AdV- VAC    CTRL SYS/Cryo Interface AdV- VAC    CTRL SYS/Cryo Interface

AdV- VAC CTRL SYS/Cryo Interface - PowerPoint Presentation

ellena-manuel
ellena-manuel . @ellena-manuel
Follow
344 views
Uploaded On 2020-01-19

AdV- VAC CTRL SYS/Cryo Interface - PPT Presentation

AdV VAC CTRL SYSCryo Interface 06Feb2013 Cryotrap cryogenics simplified sketch the electronic equipment needed to read LN2 level temperature controller of feeding valve phase separator electronics ID: 773217

equipment ln2 interface cryo ln2 equipment cryo interface vacuum alarm point temperature level remote general set signals system phase

Share:

Link:

Embed:

Download Presentation from below link

Download Presentation The PPT/PDF document "AdV- VAC CTRL SYS/Cryo Interface" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

AdV- VAC CTRL SYS/Cryo Interface 06Feb2013

Cryotrap cryogenics (simplified sketch) = the ‘electronic’ equipment needed to read LN2 level, temperature, controller of feeding valve, phase separator electronics...

‘Control System’ The general system that collect data from all vacuum equipment and operate them also by remote trough the supervisor SW. A ‘Vac Rack’ is foreseen for each crytrap, it will allow the operation of vacuum pumps and valves , and interface also with cryogenic equipment (And also interface with DAQ)

Some tasks related to cryo equipment Need to o perate cryogenic devices (adjust the set point of LN2 level, feeding valves closing, start / stop temp sensors...) from Local . And also by remote (a few of them..., normally by the general vacuum SW) Need to provide some interlocks from the ‘cryo equipments (alarms) to the ‘rest’ of the system Need also to monitor ‘most’ signals from cryo equipment and record them (normally by the general vacuum SW)

Example of interlocks Alarm of cryotrap over temperature Set point temperature reached (<80K)Alarm of high LN2 level Alarm of low LN2 levelSet point LN2 reached Phase separator alarm ...

Signals monitored by remote Most of available ones, example

‘’Interface definition & task sharing’’ Discussion about the task sharing and to prepare the exchange of information