/
Evaluator Reminders 4/15 Evaluator Reminders 4/15

Evaluator Reminders 4/15 - PowerPoint Presentation

joyousbudweiser
joyousbudweiser . @joyousbudweiser
Follow
342 views
Uploaded On 2020-10-22

Evaluator Reminders 4/15 - PPT Presentation

Jagdish Tuli National Nuclear Data Center Brookhaven National Laboratory Email Tulibnlgov Brookhaven Science Associates AdoptedReminder Adopted Properties Qrecord must be given even if nothing ID: 814928

data adopted presentation values adopted data values presentation decay gammas authors

Share:

Link:

Embed:

Download Presentation from below link

Download The PPT/PDF document "Evaluator Reminders 4/15" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

Slide1

Evaluator Reminders 4/15

Jagdish Tuli*

National Nuclear Data Center

Brookhaven National Laboratory

*Email: Tuli@bnl.gov

Brookhaven Science Associates

Slide2

Adopted-Reminder

Adopted Properties

Q-record – must be given -even if nothing known

Values from 2012, Audi masses (2012Wa38)

Give Systematic uncertainties as comments.

Slide3

Adopted-Reminder

Adopted Properties

XREF even if only one data set with gammas

BAND Identification only on first record

Slide4

Adopted-Reminder

Adopted Properties

Levels: GS and Isomers: Decay Modes and moments must be given, if known, on the continuation records. Any comments on these should be on the comment records only.

T1/2 from keyno. is not enough, include DSID

Moments – Check Nick Stone’s latest compilation

Isomer is a level with T1/2>=1 NS or if it has an IT dataset

Slide5

Extraction of data

Quote authors’ measured quantities

Document any deviationsNote authors’ assumptions

Check for missed references

Check authors’ quoted older values

Slide6

Presentation of data-1

Order of CommentsE= not needed for reactionTarget JPI should be given

Style - Keyno: measured, etc.Do not combine different kinds of data setsSpecify source of dataEnsure accuracy of values from adopted set

Do not say “from ENSDF”

Slide7

Presentation-2

Gammas order by increasing EgSignificant digitsUncertainty of 25 no longer a rigid rule

MultipletsXsection,Analyzing-power values not givenA2, A4, DCO ratios given with definition

Slide8

Presentation-3

BEL up for levels, down for gammas. Delayed gammas - give as IT decay

Slide9

Presentation-4

Normalization condition should be givenParent record, all fields should be givenReplace `/’ by `:’ for multiple ratios

Unresolved discrepancies should be pointed outE(ec),E(b-) only when accurate, measuredXUNDL data use - its evaluators’ responsibility

Slide10

Systematics

LogT1/2(alpha) vs Log E(alpha) is linearTakahashi’s gross beta decay theory reliable to better than a factor of 3

Alpha Decay HFCertain pairs of configurations lead to isomeric transitionsGS feeding from local systematicsMass systematics from Audi

Slide11

Style

APS style adoptedAmerican spellingsAccepted abbreviations

Key number when used as proper noun is plural. Space after `,’ except between key numbers, etc.Evaluator not compilerUncertainty not error.