HF test stand HF test stand

HF test stand - PowerPoint Presentation

liane-varnes
liane-varnes . @liane-varnes
Follow
440 views
Uploaded On 2016-07-17

HF test stand - PPT Presentation

Ferhat Özok Alexi Mestvirishvili E Aslı Yetkin People involved Özlem Özçelik Mithat Kaya Sevgi Tekten Yusuf Günaydin Güral Aydin ID: 408818

run led test data led run data test pmt part high comment description number rms intensity err ped type version table cern

Share:

Link:

Embed:

Download Presentation from below link

Download Presentation The PPT/PDF document "HF test stand" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

Slide1

HF test stand

Ferhat Özok, Alexi Mestvirishvili, E. Aslı YetkinPeople involved: Özlem Özçelik, Mithat Kaya, Sevgi Tekten, Yusuf Günaydin, Güral Aydin, Fikri Onur Öztırpan, Umut Kayhan Sen, Cansu Uguruyar, Thiago Dos Reis Martins Slide2

News

* We have twiki page for our test. We are putting instruction about test setup. (https://twiki.cern.ch/twiki/bin/viewauth/CMS/HF_ROBOX_TESTS_904) ✔* We have dedicated e-log under HCAL branch in CMS e-log. Name is HF upgrade tests. ✔ * signal & reference cables were labelled. cables were connected to QIEs ✔* dark boxes were installed and ready to data taking. ✔* Codes for creating XML table for DB are almost ready ✔* training was performed loading base board with PMT ✔ Data taking with Dark-boxes ✔ LED Runs were taken during training Elog link: http://cmsonline.cern.ch/cms-elog/778997* During last week we had some problems with HV Power supply(both old and new PSU). we decide to use CAEN. CAEN power supply will be used to power both boxes CAEN system was installed at 904 and ready to use ✔Slide3

(

https://twiki.cern.ch/twiki/bin/viewauth/CMS/HF_ROBOX_TESTS_904) Slide4

Labeling

Signal & reference cables are labeled as 4B-r2: PMT_4, Baseboard_B, and reference cable #2Darkboxes are labeled as Darkbox01 and Darkbox02Slide5

Darkbox 01Slide6
Slide7

Run 207

Dark Box 01Slide8

<?xml

version="1.0" encoding="UTF-8" standalone="yes"?><ROOT xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"> <HEADER> <TYPE> <EXTENSION_TABLE_NAME>HF_PMT_HIGH_LED_TEST_SUMRY</EXTENSION_TABLE_NAME> <NAME>HF PMT High Intensity LED Test Summary Data</NAME> </TYPE>

<RUN

>

<

RUN_NUMBER

>

207

</

RUN_NUMBER

>

<

RUN_TYPE

>>

High Intensity LED Test

</

RUN_TYPE

> <RUN_BEGIN_TIMESTAMP>5.08.2012 00:00:00</RUN_BEGIN_TIMESTAMP> <INITIATED_BY_USER>Ferhat_OZOK</INITIATED_BY_USER> <LOCATION>CERN</LOCATION> <COMMENT_DESCRIPTION>High Intensity LED Test</COMMENT_DESCRIPTION> </RUN> </HEADER> <DATA_SET> <VERSION>Version1</VERSION> <COMMENT_DESCRIPTION>HF PMT High Intensity LED Test Summary</COMMENT_DESCRIPTION> <PART> <SERIAL_NUMBER>JA0276</SERIAL_NUMBER> <KIND_OF_PART>HF PMT</KIND_OF_PART> </PART> <DATA> <LED_MEAN>12709.4542 </LED_MEAN> <LED_MEAN_ERR>14.0951</LED_MEAN_ERR> <LED_RMS>6.4724</LED_RMS> <LED_RMS_ERR>0.6425</LED_RMS_ERR> <PED_MEAN>106.9063</PED_MEAN> <PED_MEAN_ERR>1.8426</PED_MEAN_ERR> <PED_RMS>6.4724</PED_RMS> <PED_RMS_ERR>10.4244</PED_RMS_ERR> <HIGH_VOLT>600</HIGH_VOLT> </DATA> </DATA_SET>

Example LED Summary

XML Table For DB

Run #207 Slide9

<?xml

version="1.0" encoding="UTF-8" standalone="yes"?><ROOT xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"> <HEADER> <TYPE> <EXTENSION_TABLE_NAME>HF_PMT_TEST_POSITION</EXTENSION_TABLE_NAME> <NAME>HF PMT Test Position CERN</NAME> </TYPE> <RUN>

<RUN_NUMBER>

207

</

RUN_NUMBER

>

<

RUN_TYPE

>>

High Intensity LED Test

</

RUN_TYPE

>

<

RUN_BEGIN_TIMESTAMP

>

5.08.2012 00:00:00</RUN_BEGIN_TIMESTAMP> <INITIATED_BY_USER>Ferhat_OZOK</INITIATED_BY_USER> <LOCATION>CERN</LOCATION> <COMMENT_DESCRIPTION>High Intensity LED Test</COMMENT_DESCRIPTION> </RUN> </HEADER> <DATA_SET> <VERSION>TestVersion1</VERSION> <COMMENT_DESCRIPTION>Position of HF PMT High Intensity LED Test</COMMENT_DESCRIPTION> <PART> <SERIAL_NUMBER>JA0276</SERIAL_NUMBER> <KIND_OF_PART>HF PMT</KIND_OF_PART> </PART> <DATA> <SPIGOT>0</SPIGOT> <CHANNEL>18</CHANNEL> </DATA> </DATA_SET> <DATA_SET> <VERSION>TestVersion1</VERSION> <COMMENT_DESCRIPTION>Position of HF PMT High Intensity LED Test</COMMENT_DESCRIPTION> <PART> <SERIAL_NUMBER>JA0279</SERIAL_NUMBER> <KIND_OF_PART>HF PMT</KIND_OF_PART> </PART> <DATA> <SPIGOT>0</SPIGOT> <CHANNEL>24</CHANNEL>

</DATA> </DATA_SET>

Example LED Position

XML Table For DB

Run #207