Download Pdf The PPT/PDF document "Users Guide" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

1 User's Guide __/LA__ english
User's Guide __/LA__ english 3 1 Notes to the user4 1.1 Validity 1.2 Symbols and conventions4 1.3 Scope of delivery4 1.4 Approvals and markings 2 Safety 2.1 Intended use5 2.2 General safety notes for the position measuring system5 2.3 Explanation of the warnings 2.4 Disposal5 3 Construction and function6 3.1 Construction6 3.2 Function6 4 Installation and connection7 4.1 Installation guidelines7 4.2 Preparing for installation 4.3 Electrical connection8 4.3.1 Cable connection8 4.4 Shielding and cable routing 5 Startup 5.1 Starting up the system9 5.2 Operating notes9 6 Technical data 6.1 Accuracy10 6.2 Ambient conditions10 6.3 Supply voltage (external) 6.4 Dimensions, weights10 7 Accessories 7.1 Magnets11 8 Type code breakdown 9 Appendix 9.1 Converting units of length13 9.2 Part label13 4 1.1 Validity This guide describes the construction, function and setup options for the BTL6 Micropulse Transducer with digital interface. It applies to types BTL6-A/E500/ B50_-M (see Type code breakdown on page12). The guide is intended for qualified technical personnel. Read this guide before installing and operating the transducer. 1.2 Symbols and conventions Individual instructions are indicated by a preceding triangle. Instruction 1 Action sequences are numbered consecutively: 1. Instruction 1 2. Instruction 2 Note, tip This symbol indi

2 cates general notes. 1.3 Scope of delive
cates general notes. 1.3 Scope of delivery – BTL6 transducer – Condensed guide The magnets are available in various models and must be ordered separately. 1.4 Approvals and markings UL approval 1) File no. E227256 US Patent 5923164 The US patent was awarded in connection with this product. The CE Mark verifies that our products meet the requirements of EU Directive 2004/108/EC (EMC Directive). 1) not for BTL6-…-LA The transducer meets the requirements of the following generic standards: – EN61000-6-1 (noise immunity) – EN61000-6-2 (noise immunity) – EN61000-6-3 (emission) – EN61000-6-4 (emission) and the following product standard: – EN61326-2-3 Emission tests: – RF emission EN55016-2-3 (industrial and residential areas) Noise immunity tests: – Static electricity (ESD) EN 61000-4-2 Severity level 3 – Electromagnetic fields (RFI) EN 61000-4-3 Severity level 3 – Electrical fast transients (burst) EN 61000-4-4 Severity level 3 – Surge EN 61000-4-5 Severity level 2 – Conducted interference induced by high-frequency fields EN 61000-4-6 Severity level 3 – Magnetic fields EN 61000-4-8 Severity level 4 Compatibility tests (EMC Directive): – Agricultural and forestry machinery ISO14982 – Earth-moving m

3 achinery ISO13766 – Road vehic
achinery ISO13766 – Road vehicles ISO7637-1/2/3 – Industrial trucks EN12895 – Railway applications EN50121-3-2 – Electromagnetic HF field, 200V/m ISO11452-5 Restrictions: External protection measures must be taken: – EN50121-3-2 (burst 2kV acc. to EN61000-4-4) – ISO7637-2 pulse 5a External buffering measures must be taken: – Fluctuations and interruptions in the supply (EN50155) More detailed information on the guidelines, approvals, and standards is included in the declaration of conformity. Note on EMC characteristics (only BTL6-A/ E500/B50_-…-LA__) EMC characteristics can only be ensured if the BTL6-A/E500/B50_…-LA__ is completely installed in a grounded metal housing. 1 Notes to the user 5 2.1 Intended use The BTL6 Micropulse Transducer, together with a machine controller (e.g. PLC), comprises a position measuring system. It is intended to be installed into a machine or system. Flawless function in accordance with the specifications in the technical data is ensured only when using original BALLUFF accessories. Use of any other components will void the warranty. Opening the transducer or non-approved use are not permitted and will result in the loss of warranty and liability claims against the manufacturer. 2.2 General safety

4 notes for the position measuring system
notes for the position measuring system Installation and startup may only be performed by trained specialists with basic electrical knowledge. Qualified personnel are those who can recognize possible hazards and institute the appropriate safety measures due to their professional training, knowledge, and experience as well as their understanding of the relevant conditions pertaining to the work to be done. The operator is responsible for ensuring that local safety regulations are observed. In particular, the operator must take steps to ensure that a defect in the position measuring system will not result in hazards to persons or equipment. If defects and unresolvable faults occur in the position measuring system, take it out of service and secure against unauthorized use. 2.3 Explanation of the warnings Always observe the warnings in these instructions and the measures described to avoid hazards. The warnings used here contain various signal words and are structured as follows: SIGNAL WORD Hazard type and source Consequences if not complied with Measures to avoid hazards The individual signal words mean: NOTICE! Identifies a hazard that could damage or destroy the product. DANGER The general warning symbol in conjunction with the signal word DANGER identifies a hazard which, if not avoided, will certainly result in death

5 or serious injury . 2.4 Disposal Obs
or serious injury . 2.4 Disposal Observe the national regulations for disposal. 2 Safety 6 Fig. 3-1: 7.5Ø D163.530-125.2 2125G Ø 48 f7 Ø 38.9 13 Ø 48 f7 Ø 38.9 Ø 12 134 25.7 21 Ø 24 3 7.525 4 45° Ø46 R2 Ø24 BTL6-A/E500/B50_-…-E2/E28-… transducer, construction and function 3.1 Construction Electrical connection: The electrical connection is made via a cable or strands and is permanent (see Type code breakdown on page12). BTL housing: Housing containing the processing electronics. Fastening: The BTL transducer can be fastened in a fitting bore (Ø48H8), but must be sealed with the provided O-ring and support ring. The body of the transducer is fastened using 3M5 threaded pins at a 120° angle. The transducer with Ø10.2mm has an additional thread at the end of the rod to support larger nominal lengths. Magnet: Defines the position to be measured on the waveguide. Magnets are available in various models and must be ordered separately (see Accessories on page11). Nominal length: Defines the available measuring range. Rods with various nominal lengths from 50 mm to 2000mm are available depending on the version: – Ø10.2mm: Nominal length from 50mm to 2000mm – Ø8mm: Nominal length from 50mm to 1016mm Damping zone: Area at th

6 e end of the rod that cannot be used fo
e end of the rod that cannot be used for measurements, but which may be passed over. 3 Construction and function BTL6-…-KA BTL6-…-LA 1) Unusable area 2) Not included in scope of delivery Damping zone Magnets 1) Nominal length = Measuring range 2) 1) Version D1 G …-E2-… 10.2 mm Thread M4x4/ 6deep …-E28-… 8 mm No thread 3.2 Function The Micropulse Transducer contains the waveguide which is protected by an outer stainless steel tube (rod). A magnet is moved along the waveguide. This magnet is connected to the system part whose position is to be determined. The magnet defines the position to be measured on the waveguide. An internally generated INIT pulse interacts with the magnetic field of the magnet to generate a torsional wave in the waveguide which propagates at ultrasonic speed. The component of the torsional wave which arrives at the end of the waveguide is absorbed in the damping zone to prevent reflection. The component of the torsional wave which arrives at the beginning of the waveguide is converted by a coil into an electrical signal. The travel time of the wave is used to calculate the position. Depending on the version, this information is made available as a voltage or current output with a rising gradient. Mounting surface O-ring Support ring 7 4.1 Installation guidelines Fig. 4-1: Inst

7 allation in hydraulic cylinders Non-magn
allation in hydraulic cylinders Non-magnetizable material Fig. 4-2: MagnetNon-magnetizable material Installation in non-magnetizable material Magnetizable material If using magnetizable material, the transducer must be protected against magnetic interference through suitable measures (e.g. spacer ring made of non-magnetizable material, a suitable distance from strong external magnetic fields). Fig. 4-3: Spacer ring made of non-magnetizable Magnets Installation in magnetizable material Rod diameter Bore diameter B E2 10.2mm At least 13mm E28 8mm At least 11mm Tab. 4-1: Bore diameter if installed in a hydraulic cylinder 4.2 Preparing for installation Installation note: We recommend using non- magnetizable material to mount the transducer and magnet. Horizontal assembly: If installing horizontally with �nominal lengths 500mm, we recommend tightening the rod at the end (only possible with Ø10.2mm) or supporting it. Hydraulic cylinder: If installed in a hydraulic cylinder, ensure that the minimum value for the bore diameter of the support piston is complied with (seeTab.4-1). Fitting bore: The BLT transducer can be fastened in a fitting bore (Ø48H8), but must be sealed with the provided O-ring and support ring. The body of the transducer is fastened using 3M5 thread

8 ed pins at a 120° angle. Magnet: Vario
ed pins at a 120° angle. Magnet: Various magnets are available for the BTL6 transducer ( see Accessories on page 11). Note on EMC characteristics (only BTL6-A/E500/B50_-…-LA__) EMC characteristics can only be ensured if the BTL6-A/E500/B50_…-LA__ is completely installed in a grounded metal housing. 4 Installation and connection Headless setscrew DIN914 M5×8 8 4.3 Electrical connection Depending on the model, the electrical connection is made using a cable or strands. The connection assignments can be found in Table4-2. Note the information on shielding and cable routing. 4.3.1 Cable connection Output signals Color -A500 -B500 -B502 -B503 -E500 GY gray 0V GN green 0 to 10V 1) 0 to 5V 2) 0.25 to 4.75V 2) 0.5 to 4.5V 2) 4 to 20mA 3) Supply voltage (external) BU blue GND 4) BN brown 10 to 30VDC 1) If there is no magnet in the measuring range, a voltage of 10.2V is output as an error signal for A. 2) If there is no magnet in the measuring range, a voltage of 5.1V is output as an error signal for B. 3) If there is no magnet in the measuring range, a current of 3.6mA is output as an error signal for E. 4) Reference potential for supply voltage and EMC-GND. Tab. 4-2: Connection assignments 4 Installation and connection (conti

9 nued) 4.4 Shielding and cable routing De
nued) 4.4 Shielding and cable routing Defined ground! The transducer and the control cabinet must be at the same ground potential. Shielding To ensure electromagnetic compatibility (EMC), observe the following: – Connect transducer and controller using a shielded cable. Shielding: Braided copper shield with minimum85% coverage. – Cable version: On the transducer side, the cable shielding is connected to the housing. Ground the cable shielding on the controller side (connect with the protection ground). – Strand version: Observe note on shielding (see page7). Magnetic fields The position measuring system is a magnetostrictive system. It is important to maintain adequate distance between the transducer/holding cylinder and strong, external magnetic fields. Cable routing Do not route the cable between the transducer, controller, and power supply near high voltage cables (inductive stray noise is possible). The cable must be routed tension-free. Min. bending radius (BTL6-…-KA__) Fixed routing 3x Øcable Moved routing 7.5x Øcable Cable length The maximum cable length is 20m 1) . 1) Prerequisite: Construction, shielding and routing preclude the effect of any external noise fields. 9 5 Startup 5.1 Starting up the system DANGER Uncontrolled system movement When starting up, if the

10 position measuring system is part of a
position measuring system is part of a closed loop system whose parameters have not yet been set, the system may perform uncontrolled movements. This could result in personal injury and equipment damage. Persons must keep away from the system's hazardous zones. Startup must be performed only by trained technical personnel. Observe the safety instructions of the equipment or system manufacturer. 1. Check connections for tightness and correct polarity. Replace damaged connections. 2. Turn on the system. 3. Check measured values and adjustable parameters and readjust the transducer, if necessary. Check for the correct values at the null point and end point, especially after replacing the transducer or after repair by the manufacturer. 5.2 Operating notes – Check the function of the position measuring system and all associated components on a regular basis. – Take the position measuring system out of operation whenever there is a malfunction. – Secure the system against unauthorized use. 10 6.1 Accuracy The specifications are typical values for the BTL6-P510… at 24VDC and room temperature, with a nominal length of 500mm in conjunction with the BTL BTL magnet. The BTL is fully operational immediately, with full accuracy after warm-up. For special versions, other technical data may apply. Special v

11 ersions are indicated by the suffix -SA
ersions are indicated by the suffix -SA on the part label. Resolution (with input filter 27kHz) AB typical E typical ±1.5mV ±7µA Sampling rate with Nominal length 1300mm Nominal length 1300 1kHz 0.5kHz Non-linearity at Nominal length 500mm �Nominal length ±200µm ±0.04%FS Typ. ±0.02%FS Temperature coefficient 1) Typ. 25µm/K 6.2 Ambient conditions 2) Operating temperature 40°C to +85°C Storage temperature 40°C to +100°C Humidity  condensing Rod pressure rating (when installed in hydraulic cylinders) For Ø8mm 250bar For Ø10.2mm 350bar Shock rating per EN60068-2-27 3) 100g/6ms Continuous shock per EN60068-2-29 3) 50g/2ms Vibration per EN60068-2-6 3) (note resonant frequency of the rod) 12g, 10 to 2000Hz Degree of protection per IEC60529 KA/LA IP67 6.3 Supply voltage (external) Voltage, stabilized 5) : BTL6-_5__-… 10 to 30VDC Ripple 0.2V ss Current draw (at24VDC)  60 mA Inrush current 2.5A/2ms Typical power consumption 1.5 W Reverse polarity protection 4) Up to 40V Overvoltage protection Up to 36V Dielectric strength (GND to housing) 500VDC 6

12 .4 Dimensions, weights Rod diameter 8
.4 Dimensions, weights Rod diameter 8mm or 10.2mm Nominal length For Ø8mm 50 to 1016mm For Ø10.2mm 50 to 2000mm Weight (depends on length) Approx. 2kg/m Housing material Stainless steel1.4404 Cover material Stainless steel1.4305 Rod material Stainless steel1.4571 Rod wall thickness For Ø8mm 0.9mm For Ø10.2mm 2mm Young's modulus Approx. 200kN/mm 2 Fitting method Mounting flange BTL6-…-KA__ Cable material PUR; cULus20549 80C, 300V, internal wiring Cable temperature with fixed routing –40°C to +80°C Cable diameter Max. 4.6mm Permissible bending radius Fixed routing 13.5mm Moved 33mm 1) Nominal length = 500mm, magnet in the middle of the measuring range 2) : Use in enclosed spaces and up to a height of 2000m above sea level. 3) Individual specifications as per Balluff factory standard 4) A prerequisite is that no current can flow between GND and 0V in the event of polarity reversal. 5) : The transducer must be externally connected via a limited- energy circuit as defined in UL61010-1, a low-power source as defined in UL60950-1, or a class 2 power supply as defined in UL1310 or UL1585. 6 Technical data 11 Accessories are not included in the

13 scope of delivery and must be ordered s
scope of delivery and must be ordered separately. 7.1 Magnets Fig. 7-1: BTL-P-1013-4R BTL-P-1013-4SBTL-P-1012-4RBTL-P-1014-2R BTL-P-0814-GR-PAF Magnet installation dimensions BTL-P-1013-4R, BTL-P-1013-4S, BTL-P-1012-4R, BTL-P-1014-2R: Weight: Approx. 10g Housing: Anodized aluminum Included in the scope of delivery for the BTL-P-1013-4R, BTL-P-1013-4S, BTL-P-1012-4R: Spacer: 8mm, material: polyoxymethylene (POM) 7 Accessories 12 8 Type code breakdown BTL6 - A 5 00 - M0500 - E28 - KA05 Micropulse transducer Interface: A = Analog interface, voltage output 0 to 10V E = Analog interface, current output 4 to 20mA B = Analog interface, voltage output 0 to 5V / 0.25to4.75V / 0.5to4.5V Supply voltage: 5 = 10 to 30VDC Output gradient: 00 = rising (e.g. E_00 = 4 to 20 mA / B_00 = 0 to 5 V) - with A/E/B 02 = rising (B_02 = 0.25 to 4.75 V) - only with B 03 = rising (B_03 = 0.5 to 4.5 V) - only with B Nominal length (4-digit): M0500 = Metric specification in mm, nominal length 500mm (M0050…M2000: E2) (M0050…M1016: E28) Rod version, fastening: E2 = Mounting flange, rod diameter 10.2mm E28 = Mounting flange, rod diameter 8mm Electrical connection: KA05 = Cable, 5m LA00.3 = Strands 0.3m 13 9.1 Converting units of length 1mm=0.0393700787inches

14 mm inches 1 0.03937008 2 0.07874016 3 0
mm inches 1 0.03937008 2 0.07874016 3 0.11811024 4 0.15748031 5 0.19685039 6 0.23622047 7 0.27559055 8 0.31496063 9 0.35433071 10 0.393700787 Tab. 9-1: Conversion table mm to inches 1inch=25.4mm inch mm 1 25.4 2 50.8 3 76.2 4 101.6 5 127 6 152.4 7 177.8 8 203.2 9 228.6 10 254 Tab. 9-2: Conversion table inches to mm 9 Appendix 9.2 Part label BTL04PK12071200088888 DEBTL6-A500-M0500-E2-KA02 Fig. 9-1: BTL6 part label 1) Type 2) Ordering code 3) Serial number 3) 3) 1) 2) www.balluff.com www.balluff.com english BTL6-A/E500/B50 Micropulse Transducer - Rod Style english BTL6-A/E500/B50 Micropulse Transducer - Rod Style No. 898090-726 EN · 00.000000 · H13; Subject to modication. www.balluff.com Headquarters Germany Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.F. Phone + 49 7158 173-0 Fax +49 7158 5010 balluff@balluff.de Global Service Center Germany Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.F. Phone +49 7158 173-370 Fax +49 7158 173-691 service@balluff.de US Service Center USA Balluff Inc. 8125 Holton Drive Florence, KY 41042 Phone (859) 727-2200 Toll-free 1-800-543-8390 Fax (859) 727-4823 technicalsupport@balluff.com CN Service Center China Balluff (Shanghai) trading Co., ltd. Room 1006, Pujian Rd. 145. Shanghai, 200127, P.R. China Phone +86 (21) 5089 9970 Fax +86 (21) 5089 9975 service@ballu