This cable is typically used for industrial equipment control electric valve actuation and remote signaling as well as communications and broadcast applications These designs are available in a wide variety of insulation and jacketing materials as w ID: 25847

This cable typically

Share:

Link:

Embed:

Download Presentation from below link

Download Pdf The PPT/PDF document "Electronics The multiconductor array of ..." is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

6Electronics The multi-conductor array ofcommunication and controlcable facilitates cable pull-insand single-site installations.This cable is typically usedfor industrial equipmentcontrol, electric valve actuationand remote signaling, as wellas communications andbroadcast applications. Thesedesigns are available in a widevariety of insulation andjacketing materials, as well asshield designs to alleviateunwanted circuit noise.BICCGeneralÕs Carol ¨ Brandproducts are manufactured tomeet the latest UL, CSA, andNEC requirements andapprovals.A Design To Meet EveryApplicationPVC/PVC designs employpolyvinyl chloride insulationsand jackets capable of meetingeveryday, general purposeapplications.PE or PP/PVC designsemploy high qualitypolyethylene or polypropyleneinsulations to assure faithfulreproduction of transmittedsignals across interconnectioncircuits.Foamed PP/PVC designsuse high speed, foamedpolypropylene insulations forlong distance, critical circuits,which would not perform ifhigher loss insulations wereemployed.Rubber/Rubber is typicallyemployed in installationscharacterized as severelyhostile environments, wherethese designs provideunsurpassed service life.Rubber/Carolprene ¨ offersthe ultimate performance for ¨ jackethas been proven time andagain to withstand all types ofabuse, both mechanical andchemical. IndexPageMulti-Conductor, Unshielded7-12Power-Limited Tray Cable, Unshielded13Multi-Conductor, Rubber, Unshielded14Multi-Conductor, Foil Shield15-17Power-Limited Tray Cable, Foil Shield18Multi-Conductor, Spiral Shield19Multi-Conductor, Braid Shield20-23Multi-Conductor, Foil/Braid Shield24Multi-Conductor, Rubber, Braid Shield25Multi-Conductor, Carolprene, ¨ Braid Shield26 Communication & Control Cable, Multi-Conductor2 S p o o l - P a c ¨ C a r t o n s P u l l - P a c ¨ C a r t o n s R e e l s S p o o l s 7 ElectronicsCommunication & Control Cable, Multi-Conductor CATALOGNUMBERNO. OFCOND.AWGSIZECOND.STRAND.NOM. INSULATION THICKNESSINCHES C4008 C4310 C4311 C2754 C2755232232 22 22 01 91 9S o l i dS o l i dS o l i dS o l i dS o l i d mm 0 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 2 50 . 2 50 . 2 50 . 2 50 . 2 5 NOM. JACKET THICKNESSINCHES mm 0 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 8 10 . 8 10 . 8 10 . 8 10 . 8 1 NOMINAL O.D.NOM.C-C CAP.*pF/ftINCHES mm 0 . 1 5 50 . 1 6 10 . 1 6 80 . 1 7 60 . 1 8 43 . 9 34 . 0 94 . 2 74 . 4 74 . 6 7 COLORCODE B l a c k /R e dB l a c k /R e d /W h i t eB l a c k /R e dB ro w n /Ta nB ro w n /G r a y /Ta n2 5 . 02 5 . 02 8 . 02 9 . 52 9 . 5 Product Construction:Conductor: ¥Fully annealed tinned copper per ASTM B-33¥Fully annealed solid bare copper to ASTM B-3, (C2754, C2755) Insulation: ¥Premium grade color coded S-R PVC per UL 1061 Jacket: ¥PVC, gray¥ Temperature Range: Ð20¡C to +80¡C Applications: ¥Public address systems¥Intercoms¥Remote control circuits¥ Suggested voltage rating: 300 volts Compliances: ¥NEC Article 800 Type CM (UL: 75¡C)¥UL Style 2464 (UL: 80¡C 300V)¥CSA CMG (CSA: 60¡C)¥Designed to Meet UL 70,000 BTU VerticalTray Flame Test¥ Passes CSA CMG Flame Test Packaging: ¥1000' (305 m) Spools¥500' (152 m) Spools¥Other put-ups availableÑconsult Customer Service Multi-Conductor, Unshielded UL 2464, NEC Type CM (UL) c(UL), CSA CMG *Capacitance between conductors 19 20 21 22 23 2425 8 Communication & Control Cable, Multi-ConductorElectronics Multi-Conductor, Unshielded UL 2464, NEC Type CM (UL) c(UL), CSA CMG CATALOGNUMBERNO. OFCOND.AWGSIZECOND.STRAND.NOM. INSULATION THICKNESSINCHES C2461 C2462 C2463 C2464 C2466 C2488 C2465 C2470 C2471 C2467 C2473 C2475C2476234567891 01 21 52 02 52 42 42 42 42 42 42 42 42 42 42 42 42 47 / 3 27 / 3 27 / 3 27 / 3 27 / 3 27 / 3 27 / 3 27 / 3 27 / 3 27 / 3 27 / 3 27 / 3 27 / 3 2 mm 0 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 2 50 . 2 50 . 2 50 . 2 50 . 2 50 . 2 50 . 2 50 . 2 50 . 2 50 . 2 50 . 2 50 . 2 50 . 2 5 NOM. JACKET THICKNESSINCHES mm 0 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 1 NOMINAL O.D.NOM.C-C CAP.*pF/ftINCHES mm 6.20 6.38 7.67 COLORCODE 23.0 Product Construction:Conductor: ¥24 AWG fully annealed stranded tinnedcopper per ASTM B-33 Insulation: ¥Premium grade color coded S-R PVC per UL 1061¥Color Code: See charts below Jacket: ¥T Applications: ¥Public address systems¥Intercoms¥Internal telephones ¥Remote control circuits¥Suitable for EIA RS-232 applications¥Suggested voltage rating: 300 volts Features: ¥Easy to terminate¥Excellent electrical properties ¥Tinned conductors provide excellentcorrosion resistance¥Assists soldering applications Compliances: ¥NEC Article 800 Type CM (UL: 75¡C)¥UL Style 2464 (UL: 80¡C, 300V)¥CSA CMG (CSA: 60¡C)¥Designed to Meet UL 70,000 BTU VerticalTray Flame Test¥Passes CSA CMG Flame Test Packaging: ¥1000' (305 m) Spools or Reels¥500' (152 m) Spools or Reels¥Other put-ups availableÑconsult Customer Service *Capacitance between conductors Color Code Chart 1 - For cables up to and including 12 conductors 1 2 3 4 56 NO. OFCOND.COLOR B l a c kW h i t eR e dG re e nB ro w nB l u e 7 8 9 10 1112 NO. OFCOND.COLOR O r a n g eYe l l o wVi o l e tG r a yP i n kTa n Color Code Chart 2 Per ICEA - For cables of 15 thru 25 conductors 1 2 3 4 5 6 7 89 NO. OFCOND.COLOR B l a c kW h i t eR e dG re e nO r a n g eB l u eW h i t e / B l a c kR e d / B l a c kG re e n / B l a c k 10 11 12 13 14 15 16 1718 NO. OFCOND.COLOR O r a n g e / B l a c kB l u e / B l a c kB l a c k / W h i t eR e d / W h i t eG re e n / W h i t eB l u e / W h i t eB l a c k / R e dW h i t e / R e dO r a n g e / R e d NO. OFCOND.COLOR B l u e / R e dR e d / G re e nO r a n g e / G re e nB l a c k / W h i t e / R e dW h i t e / B l a c k / R e dR e d / B l a c k / W h i t eG re e n / B l a c k / W h i t e 9 ElectronicsCommunication & Control Cable, Multi-Conductor Product Construction:Conductor: ¥22 AWG fully annealed, stranded tinnedcopper per ASTM B-33 Insulation: ¥Premium grade color coded S-R PVC per UL 1061¥Color Code: See charts below Jacket: ¥T Applications: ¥Public address systems¥Intercoms¥Internal telephones¥Remote control circuits¥Suitable for EIA RS-232 applications¥Suggested voltage rating: 300 volts Features: ¥Easy to terminate¥Excellent electrical properties¥Tinned conductors provide excellentcorrosion resistance¥Assists soldering applications Compliances: ¥NEC Article 800 Type CM (UL: 75¡C)¥UL Style 2464 (UL: 80¡C, 300V)¥CSA CMG (CSA 80¡C)¥Designed to Meet UL 70,000 BTU VerticalTray Flame Test¥Passes CSA CMG Flame Test Packaging: ¥1000' (305 m) Spools or Reels¥500' (152 m) Spools or Reels¥Other put-ups availableÑconsult Customer Service Multi-Conductor, Unshielded UL 2464, NEC Type CM (UL) c(UL), CSA CMG CATALOGNUMBERNO. OFCOND.AWGSIZECOND.STRAND.NOM. INSULATION THICKNESSINCHES C6348  C4062 C4063 C4064 C4066 C4088 C4065 C4070 C4071 C4067 C4073 C4069 C4075 C4076 C4077 C4078C4079234567891 01 21 51 82 02 53 04 05 02 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 27 / 3 07 / 3 07 / 3 07 / 3 07 / 3 07 / 3 07 / 3 07 / 3 07 / 3 07 / 3 07 / 3 07 / 3 07 / 3 07 / 3 07 / 3 07 / 3 07 / 3 0 mm 0 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 0 1 00 . 2 50 . 2 50 . 2 50 . 2 50 . 2 50 . 2 50 . 2 50 . 2 50 . 2 50 . 2 50 . 2 50 . 2 50 . 2 50 . 2 50 . 2 50 . 2 50 . 2 5 NOM. JACKET THICKNESSINCHES mm 0 . 0 1 50 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 3 80 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 1 NOMINAL O.D.NOM.C-C CAP.*pF/ftINCHES mm 4.47 5.16 8.08 8.48 COLORCODE 1 2 25.5 25.5 25.5 25.5 *Capacitance between conductors CM-CSA CMG Only Color Code Chart 2 Per ICEA - For cables of 15 thru 50 conductors 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1617 NO. OFCOND.COLOR B l a c kW h i t eR e dG re e nO r a n g eB l u eW h i t e / B l a c kR e d / B l a c kG re e n / B l a c kO r a n g e / B l a c kB l u e / B l a c kB l a c k / W h i t eR e d / W h i t eG re e n / W h i t eB l u e / W h i t eB l a c k / R e dW h i t e / R e d 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 3334 NO. OFCOND.COLOR O r a n g e / R e dB l u e / R e dR e d / G re e nO r a n g e / G re e nB l a c k / W h i t e / R e dW h i t e / B l a c k / R e dR e d / B l a c k / W h i t eG re e n / B l a c k / W h i t eO r a n g e / B l a c k / W h i t eB l u e / B l a c k / W h i t eB l a c k / R e d / G re e nW h i t e / R e d / G re e nR e d / B l a c k / G re e nG re e n / B l a c k / O r a n g eO r a n g e / B l a c k / G re e nB l u e / W h i t e / O r a n g eB l a c k / W h i t e / O r a n g e 35 36 37 38 39 40 41 42 43 44 45 46 47 48 4950 NO. OFCOND.COLOR W h i t e / R e d / O r a n g eO r a n g e / W h i t e / B l u eW h i t e / R e d / B l u eB l a c k / W h i t e / G re e nW h i t e / B l a c k / G re e nR e d / W h i t e / G re e nG re e n / W h i t e / B l u eO r a n g e / R e d / G re e nB l u e / R e d / G re e nB l a c k / W h i t e / B l u eW h i t e / B l a c k / B l u eR e d / W h i t e / B l u eG re e n / O r a n g e / R e dO r a n g e / R e d / B l u eB l u e / R e d / O r a n g eB l a c k / O r a n g e / R e d Color Code Chart 1 - For cables up to and including 12 conductors 1 2 3 4 56 NO. OFCOND.COLOR B l a c kW h i t eR e dG re e nB ro w nB l u e 7 8 9 10 1112 NO. OFCOND.COLOR O r a n g eYe l l o wVi o l e tG r a yP i n kTa n 10 Communication & Control Cable, Multi-ConductorElectronics Multi-Conductor, Unshielded UL 2464, NEC Type CM (UL) c(UL), CSA CMG CATALOGNUMBERNO. OFCOND.AWGSIZECOND.STRAND.NOM. INSULATION THICKNESSINCHES C6351  C6352 C6353 C6355 C6356 C6357 C6360 C6358C2830  C2831 C2404 C2420 C2421 C2422 C2412 C2423 C2424C24332345791 21 52345791 21 51 92 52 02 02 02 02 02 02 02 01 81 81 81 81 81 81 81 81 81 87 / 2 87 / 2 87 / 2 87 / 2 87 / 2 87 / 2 87 / 2 87 / 2 81 6 / 3 01 6 / 3 01 6 / 3 01 6 / 3 01 6 / 3 01 6 / 3 01 6 / 3 01 6 / 3 01 6 / 3 01 6 / 3 0 mm 0 . 0 1 60 . 0 1 60 . 0 1 60 . 0 1 60 . 0 1 60 . 0 1 60 . 0 1 60 . 0 1 60 . 0 1 60 . 0 1 60 . 0 1 60 . 0 1 60 . 0 1 60 . 0 1 60 . 0 1 60 . 0 1 60 . 0 1 60 . 0 1 60 . 4 10 . 4 10 . 4 10 . 4 10 . 4 10 . 4 10 . 4 10 . 4 10 . 4 10 . 4 10 . 4 10 . 4 10 . 4 10 . 4 10 . 4 10 . 4 10 . 4 10 . 4 1 NOM. JACKET THICKNESSINCHES mm 0 . 0 2 50 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 2 50 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 6 40 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 6 40 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 1 NOMINAL O.D.NOM.C-C CAP.*pF/ftINCHES mm 11.30 COLORCODE B l a c k /R e d1111122B l a c k /R e d1111122222 6 . 02 6 . 02 6 . 02 6 . 02 6 . 02 6 . 02 6 . 02 6 . 02 8 . 02 8 . 02 8 . 02 8 . 02 8 . 02 8 . 02 8 . 02 8 . 02 8 . 02 8 . 0 Product Construction:Conductor: ¥20 or 18 AWG fully annealed stranded,tinned copper per ASTM B-33 Insulation: ¥Premium grade color coded PVC per UL 1007¥Color Code: See charts below Jacket: ¥T Applications: ¥Public address systems¥Intercoms¥Internal telephones¥Remote control circuits¥Suitable for EIA RS-232 applications¥Suggested voltage rating: 300 volts Compliances: ¥NEC Article 800 Type CM (UL: 75¡C)¥UL Style 2464 (UL: 80¡C, 300V)¥CSA CMG (CSA: 60¡C)¥Designed to Meet UL 70,000 BTU VerticalTray Flame Test¥Passes CSA CMG Flame Test Packaging: ¥1000' (305 m) Spools or Reels¥500' (152 m) Spools or Reels¥Other put-ups availableÑconsult Customer Service *Capacitance between conductors CM (UL) c(UL), CSA CMG Only Color Code Chart 1 - For cables up to and including 9 conductors 1 2 3 45 NO. OFCOND.COLOR B l a c kW h i t eR e dG re e nB ro w n 6 7 89 NO. OFCOND.COLOR B l u eO r a n g eYe l l o wVi o l e t Color Code Chart 2 Per ICEA - For cables of 12 thru 25 conductors 1 2 3 4 5 6 7 89 NO. OFCOND.COLOR B l a c kW h i t eR e dG re e nO r a n g eB l u eW h i t e / B l a c kR e d / B l a c kG re e n / B l a c k 10 11 12 13 14 15 16 1718 NO. OFCOND.COLOR O r a n g e / B l a c kB l u e / B l a c kB l a c k / W h i t eR e d / W h i t eG re e n / W h i t eB l u e / W h i t eB l a c k / R e dW h i t e / R e dO r a n g e / R e d 19 20 21 22 23 2425 NO. OFCOND.COLOR B l u e / R e dR e d / G re e nO r a n g e / G re e nB l a c k / W h i t e / R e dW h i t e / B l a c k / R e dR e d / B l a c k / W h i t eG re e n / B l a c k / W h i t e 11 ElectronicsCommunication & Control Cable, Multi-Conductor Product Construction:Conductor: ¥16 thru 12 AWG fully annealed strandedtinned copper per ASTM B-33 Insulation: ¥Premium grade color coded PVC¥Color Code: See chart below Jacket: ¥T Applications: ¥Public address systems¥Intercoms¥Internal telephones¥Remote control circuits¥Suitable for EIA RS-232 applications¥Suggested voltage rating: 300 volts Compliances: ¥NEC Article 725 Type CL3 (UL: 75¡C)¥NEC Article 800 Type CM (UL: 75¡C)¥UL Style 2464 (UL: 80¡C, 300V)¥UL Style 2587 (UL: 90¡C, 600V)¥CSA CMG (CSA: 60¡C)¥Designed to Meet UL 70,000 BTU VerticalTray Flame Test¥Passes CSA CMG Flame Test Packaging: ¥1000' (305 m) Spools or Reels¥500' (152 m) Spools or Reels¥Other put-ups availableÑconsult Customer Service Multi-Conductor, Unshielded UL 2464, UL 2587, NEC Type CL3 and CM (UL) c(UL), CSA CMG CATALOGNUMBERNO. OFCOND.AWGSIZECOND.STRAND.NOM. INSULATION THICKNESSINCHES C2405 C2406 C2425 C2434 C2426 C2443 C2435 C2427 C2428 C2429C243623457891 21 51 92 51 61 61 61 61 61 61 61 61 61 61 61 9 / . 0 1 1 71 9 / . 0 1 1 71 9 / . 0 1 1 71 9 / . 0 1 1 71 9 / . 0 1 1 71 9 / . 0 1 1 71 9 / . 0 1 1 71 9 / . 0 1 1 71 9 / . 0 1 1 71 9 / . 0 1 1 71 9 / . 0 1 1 7 mm 0 530 530 530.53 NOM. JACKET THICKNESSINCHES mm 0.81 0.81 0.81 0.81 NOMINAL O.D.NOM.C-C CAP.*pF/ftINCHES mm 0 . 2 6 80 . 2 8 30 . 3 0 60 . 3 3 40 . 3 6 40 . 3 9 50 . 4 2 50 . 4 7 90 . 5 3 00 . 5 6 40 . 6 5 76 . 8 17 . 1 97 . 7 78 . 4 89 . 2 51 0 . 0 31 0 . 8 01 2 . 1 71 3 . 4 61 4 . 3 31 6 . 6 9 2 8 . 02 8 . 02 8 . 02 8 . 02 8 . 02 8 . 02 8 . 02 8 . 02 8 . 02 8 . 02 8 . 0 NEC TYPE CM, UL STYLE 2464 (300 volts) C2409   C2430 C2437 C2431 19/.0147 NEC TYPE CL3, UL STYLE 2587 (600 volts) *Capacitance between conductors CL3, UL2587, CSA CMH Only Color Code Chart Per ICEA 1 2 3 4 5 6 7 89 NO. OFCOND.COLOR B l a c kW h i t eR e dG re e nO r a n g eB l u eW h i t e / B l a c kR e d / B l a c kG re e n / B l a c k 10 11 12 13 14 15 16 1718 NO. OFCOND.COLOR O r a n g e / B l a c kB l u e / B l a c kB l a c k / W h i t eR e d / W h i t eG re e n / W h i t eB l u e / W h i t eB l a c k / R e dW h i t e / R e dO r a n g e / R e d 19 20 21 22 23 2425 NO. OFCOND.COLOR B l u e / R e dR e d / G re e nO r a n g e / G re e nB l a c k / W h i t e / R e dW h i t e / B l a c k / R e dR e d / B l a c k / W h i t eG re e n / B l a c k / W h i t e 12 Communication & Control Cable, Multi-ConductorElectronics Multi-Conductor, Unshielded UL 2464, NEC Type CM (UL) c(UL), CSA CMG C4081 C4082 C4083 C408467894 - 2 22 - 1 85 - 2 22 - 1 86 - 2 22 - 1 87 - 2 22 - 1 87 / 3 01 6 / 3 07 / 3 01 6 / 3 07 / 3 01 6 / 3 07 / 3 01 6 / 3 0 0 . 0 1 00 . 0 1 60 . 0 1 00 . 0 1 60 . 0 1 00 . 0 1 60 . 0 1 00 . 0 1 60 . 2 50 . 4 10 . 2 50 . 4 10 . 2 50 . 4 10 . 2 50 . 4 1 0 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 8 10 . 8 10 . 8 10 . 8 1 0 . 2 4 40 . 2 5 30 . 2 6 30 . 2 7 36 . 2 06 . 4 36 . 6 96 . 9 42 5 . 52 8 . 02 5 . 52 8 . 02 5 . 52 8 . 02 5 . 52 8 . 0 Product Construction:Conductor: ¥22 thru 18 fully annealed stranded tinnedcopper per ASTM B-33 Insulation: ¥Premium grade color coded PVC (18 AWG),S-R PVC (22 AWG)¥ Color Code: See chart below Jacket: ¥PVC, gray¥ Temperature Range: Ð20¡C to +80¡C Applications: ¥TV antenna rotor control¥Satellite actuator control¥Public address systems¥ Suggested voltage rating: 300 volts Features: ¥Tinned copper conductors provide excellentcorrosion resistance¥ Assists with soldering applications Compliances: ¥NEC Article 800 Type CM (UL: 75¡C)¥UL Style 2464 (UL: 80¡C, 300V)¥CSA CMG (CSA: 60¡C)¥Designed to Meet UL 70,000 BTU VerticalTray Flame Test¥ Passes CSA CMG Flame Test Packaging: ¥1000' (305 m) Spools or Reels¥500' (152 m) Spools or Reels¥Other put-ups availableÑconsult Customer Service *Capacitance between conductors CATALOGNUMBERNO. OFCOND.AWGSIZECOND.STRAND.NOM. INSULATION THICKNESSINCHES mm NOM. JACKET THICKNESSINCHES mm NOMINAL O.D.NOM.C-C CAP.*pF/ftINCHES mm Color Code Chart 118 ga. 2 122 ga. 2 3 4 5 67 NO. OF COND.COLOR B l a c kW h i t eR e dG re e nB ro w nB l u eO r a n g eYe l l o wVi o l e t 13 ElectronicsCommunication & Control Cable, Multi-Conductor Product Construction:Conductor: ¥22 thru 12 AWG fully annealed strandedtinned copper per ASTM B-33 Insulation: ¥ Premium grade color coded PVC¥Color Code: See chart below Jacket: ¥ PVC, gray¥ Temperature Range: Ð20ûC to +105¡C Applications: ¥Cable tray installations¥ Power limited circuits¥Intercom systems¥ Business machines¥Cash registers¥ Automatic valve control systems¥ Irrigation systems¥Suggested voltage rating: 300 volts¥ Burglar Alarms Features: ¥ Sunlight resistant PVC jacket¥UL rated for cable tray use Compliances: ¥NEC Article 725 Power-Limited Tray Cable(UL: 105¡C, 300V)¥Meets UL 70,000 BTU Vertical Tray Flame Test Packaging: ¥ 1000' (305 m) Spools or Reels¥500' (152 m) Spools or Reels¥Other put-ups availableÑconsult Customer Service Power-Limited Tray Cable, Unshielded NEC Type PLTC C0431 C0432 C0433 C0434 C0435 C0436 C0444 C0437 C0438 C0439 C0440C04412323234232322 22 22 02 01 81 81 81 61 61 41 41 27 / 3 07 / 3 07 / 2 87 / 2 81 6 / 3 01 6 / 3 01 6 / 3 01 9 / . 0 1 1 71 9 / . 0 1 1 71 9 / . 0 1 4 71 9 / . 0 1 4 71 9 / . 0 1 8 5 0 . 0 1 30 . 0 1 30 . 0 1 30 . 0 1 30 . 0 1 30 . 0 1 30 . 0 1 30 . 0 1 30 . 0 1 30 . 0 1 30 . 0 1 30 . 0 1 30 . 3 30 . 3 30 . 3 30 . 3 30 . 3 30 . 3 30 . 3 30 . 3 30 . 3 30 . 3 30 . 3 30 . 3 3 0 . 0 3 70 . 0 3 70 . 0 3 70 . 0 3 70 . 0 3 70 . 0 3 70 . 0 3 70 . 0 3 70 . 0 3 70 . 0 4 20 . 0 4 20 . 0 4 20 . 9 40 . 9 40 . 9 40 . 9 40 . 9 40 . 9 40 . 9 40 . 9 40 . 9 41 . 0 71 . 0 71 . 0 7 5.74 6.53 2 5 . 52 5 . 52 8 . 02 8 . 03 0 . 03 0 . 03 0 . 03 4 . 03 4 . 03 7 . 03 7 . 04 0 . 0 *Capacitance between conductors CATALOGNUMBERNO. OFCOND.AWGSIZECOND.STRAND.NOM. INSULATION THICKNESSINCHES mm NOM. JACKET THICKNESSINCHES mm NOMINAL O.D.NOM.C-C CAP.*pF/ftINCHES mm Color Code Chart 1 2 34 NO. OF COND.COLOR B l a c kR e dW h i t eG re e n 14 Communication & Control Cable, Multi-ConductorElectronics Multi-Conductor, Rubber, Unshielded CATALOGNUMBERNO. OFCOND.AWGSIZECOND.STRAND.NOM. INSULATION THICKNESSNOM. JACKET THICKNESS NOMINAL O.D.INCHESmmINCHESmmINCHESmm C3602 C3603 C3604 C3605 C3606 C3607 C3608C361023456781 02 02 02 02 02 02 02 02 02 6 / 3 42 6 / 3 42 6 / 3 42 6 / 3 42 6 / 3 42 6 / 3 42 6 / 3 42 6 / 3 4 0 . 0 2 00 . 0 2 00 . 0 2 00 . 0 2 00 . 0 2 00 . 0 2 00 . 0 2 00 . 0 2 00 . 5 10 . 5 10 . 5 10 . 5 10 . 5 10 . 5 10 . 5 10 . 5 10 . 0 3 50 . 0 3 50 . 0 3 50 . 0 3 50 . 0 3 50 . 0 3 50 . 0 3 50 . 0 3 50 . 8 90 . 8 90 . 8 90 . 8 90 . 8 90 . 8 90 . 8 90 . 8 90 . 2 3 00 . 2 5 50 . 2 7 50 . 3 0 00 . 3 1 50 . 3 4 70 . 3 6 00 . 4 1 05 . 8 46 . 4 86 . 9 97 . 6 28 . 0 08 . 8 19 . 1 41 0 . 4 1 Product Construction:Conductor: ¥20 AWG fully annealed stranded tinnedcopper per ASTM B-33 Insulation: ¥Premium grade color coded rubber¥ Color Code: See chart below Jacket: ¥T Applications: ¥Energy management systems¥Control circuits¥ Fire alarm control¥Broadcast and studio requirements¥Suggested voltage rating: 350 volts Features: ¥ Excellent impact resistance¥High level of abrasion resistance¥High flexibility¥Excellent mechanical strength¥Excellent moisture resistance Packaging: ¥ 1000' (305 m) Spools or Reels¥ 500' (152 m) Spools or Reels¥Other put-ups availableÑconsult Customer Service Color Code Chart 1 2 3 4 5 6 7 8 910 NO. OF COND.COLOR B l a c kW h i t eR e dG re e nB l u eB ro w nYe l l o wO r a n g eG r a yVi o l e t 15 ElectronicsCommunication & Control Cable, Multi-Conductor C2537 Product Construction:Conductor: ¥24 thru 12 AWG fully annealed solid orstranded tinned copper per ASTM B-33 Insulation: ¥Premium grade color coded polyethylene¥ Premium grade color coded polypropylene¥Color Code: See charts below Shield: ¥100% Flexfoil ¨ aluminum/polyester,25% overlap, foil facing out¥Stranded tinned copper drain wire Jacket: ¥T Applications: ¥ Recording studios and sound stages¥ Broadcast and sound systems¥Computers¥ Industrial equipment control¥Suggested voltage rating: 300 or 600 volts Features: ¥Excellent electrical properties¥Superior shielding effectiveness ¥25% shield overlap provides excellentshielding efficiency¥ Good flexibility Compliances: ¥ UL Style 2092 (UL: 60¡C, 300V)¥UL Style 2093 (UL: 60¡C, 300V)¥UL Style 2094 (UL: 60¡C, 300V)¥ UL Style 2106 (UL: 60¡C, 600V)¥UL Style 2107 (UL: 60¡C, 600V)¥ UL Style 2464 (UL: 80¡C, 300V)¥ NEC Article 725 Type CL2 (UL: 75¡C)¥ NEC Article 800 Type CM (UL: 75¡C)¥Designed to Meet UL 70,000 BTU VerticalTray Flame Test¥CSA CMH (CSA60ûC)¥Passes CSA CMH Flame Test Packaging: ¥ 1000' (305 m) Spools or Reels¥500' (152 m) Spools or Reels¥Other put-ups available - consultCustomer Service Multi-Conductor, Foil Shield NEC Type CL2 and CM (UL) c(UL) CMH CATALOGNUMBERNO. OFCOND.AWGSIZECOND.STRAND.NOM. INSULATION THICKNESSNOM. JACKET THICKNESS NOMINAL O.D.NOM. CAP.*** AB C2513 C2514 C2524C253422222 42 22 01 87 / 3 27 / 3 07 / 2 81 6 / 3 0 0 . 0 1 60 . 0 1 60 . 0 1 60 . 0 1 80 . 4 10 . 4 10 . 4 10 . 4 60 . 0 2 60 . 0 2 60 . 0 3 00 . 0 3 00 . 6 60 . 6 60 . 7 60 . 7 60 . 1 6 70 . 1 7 90 . 2 0 30 . 2 3 34 . 2 44 . 5 55 . 1 65 . 9 22 3 . 02 6 . 03 1 . 02 4 . 04 2 . 04 7 . 05 6 . 04 3 . 0 UL STYLE 2092, CM (UL) c(UL) CMH, 300V C2526 C2528 C2525C253533332 22 02 01 87 / 3 07 / 2 87 / 2 81 6 / 3 0 0 . 0 1 60 . 0 1 60 . 0 1 60 . 0 1 80 . 4 10 . 4 10 . 4 10 . 4 60 . 0 3 00 . 0 3 00 . 0 3 00 . 0 3 00 . 7 60 . 7 60 . 7 60 . 7 60 . 1 9 60 . 2 1 00 . 2 1 30 . 2 4 74 . 9 85 . 3 45 . 4 16 . 2 72 5 . 02 7 . 02 9 . 02 2 . 04 5 . 05 1 . 05 2 . 04 0 . 0 UL STYLE 2093, CM (UL) c(UL) CMH, 300V Color Code Chart #1Color Code Chart #1Color Code Chart #1Color Code Chart #1PVC Insulation, Color Code Chart #2Polypropylene Insulation, Color Code Chart #2***A - Capacitance between conductors***B - Capacitance between one conductor and other conductors connected to shield*CM (UL) c(UL) C2523C2555442 22 07 / 3 07 / 2 8 0 . 0 1 60 . 0 1 60 . 4 10 . 4 10 . 0 3 00 . 0 3 00 . 7 60 . 7 60 . 2 1 30 . 2 3 45 . 4 15 . 9 42 3 . 02 6 . 04 2 . 04 7 . 0 UL STYLE 2094, CM (UL) c(UL) CMH, 300V C2536* C2538 * * C2539 * * 2221 61 41 21 9 / . 0 1 1 71 9 / . 0 1 4 71 9 / . 0 1 8 5 0 . 0 3 20 . 0 3 20 . 0 3 20 . 8 10 . 8 10 . 8 10 . 0 3 20 . 0 3 20 . 0 4 00 . 8 10 . 8 11 . 0 20 . 3 0 20 . 3 3 50 . 3 7 67 . 6 78 . 5 19 . 5 52 7 . 03 1 . 03 5 . 04 9 . 05 6 . 06 3 . 0 UL STYLE 2106, CSA, 600V C2515 C2516C25172232 22 22 2S o l i d7 / 3 07 / 3 0 0 . 0 0 70 . 0 0 80 . 0 0 80 . 1 80 . 2 00 . 2 00 . 0 2 00 . 0 2 00 . 0 2 00 . 5 10 . 5 10 . 5 10 . 1 2 40 . 1 3 70 . 1 4 43 . 1 53 . 4 83 . 6 64 0 . 03 4 . 03 2 . 07 6 . 06 7 . 06 0 . 0 CM (UL) c(UL) CMH, 300V 0 . 0 3 20 . 8 10 . 0 3 20 . 8 10 . 3 2 68 . 2 82 6 . 04 6 . 0 UL STYLE 2107, CM (UL) c(UL) CMH, 600V 0 . 0 1 20 . 3 00 . 0 2 50 . 6 40 . 1 8 04 . 5 75 9 . 01 1 0 . 0 UL STYLE 2464, CL2/CM (UL) c(UL) CMH, 300VColor Code Chart 1 1 2 34 NO. OF COND.COLOR B l a c kN a t u r a lR e dG re e n Color Code Chart 2 1 23 NO. OF COND.COLOR B l a c kR e dC l e a r 16 Communication & Control Cable, Multi-ConductorElectronics Multi-Conductor, Foil Shield UL 2464, NEC Type CM (UL) c(UL), CSA CMG Product Construction:Conductor: ¥18 AWG fully annealed stranded tinnedcopper per ASTM B-33 Insulation: ¥Premium grade color coded S-R PVC¥ Color Code: See chart below Shield: ¥100% Flexfoil ¨ aluminum/polyester,25% overlap, foil facing out¥ Stranded tinned copper drain wire Jacket: ¥PVC, gray¥ Temperature Range: Ð20¡C to +80¡C Applications: ¥Audio, broadcast, instrumentation andsound systems¥ Suggested voltage rating: 300 volts Compliances: ¥NEC Article 800 Type CM (UL: 75ûC)¥UL Style 2464 (UL: 80ûC, 300V)¥CSA CMG (60¡C)¥Designed to Meet UL 70,000 BTU VerticalTray Flame Test¥Passes CSA CMG Flame Test Packaging: ¥1000' (305 m) Spools or Reels¥ 500' (152 m) Spools or Reels¥Other put-ups availableÑconsultCustomer Service C2543 41 81 9 / 3 0 0 . 0 1 00 . 2 50 . 0 3 20 . 8 10 . 2 3 86 . 0 55 09 0 *A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield Color Code Chart 1 2 34 NO. OF COND.COLOR B l a c kR e dW h i t eG re e n CATALOGNUMBERNO. OFCOND.AWGSIZECOND.STRAND.NOM. INSULATION THICKNESSNOM. JACKET THICKNESS NOMINAL O.D.NOM. CAP.* AB 17 ElectronicsCommunication & Control Cable, Multi-Conductor Product Construction:Conductor: ¥22 thru 18 AWG fully annealed strandedtinned copper per ASTM B-33 Insulation: ¥Premium grade color coded polypropyleneor polyethylene¥Color Code: See charts below Shield: ¥100% aluminum/polyester foil ÒbondedÓ to jacket, foil facing in¥Stranded tinned copper drain wire Jacket: ¥ PVC, gray¥ Temperature Range: Ð20¡C to +80¡C Applications: ¥100% shielded cable where RF shielding is required¥Control circuits¥ Data and signal transmission¥ Computer interconnections¥Suggested voltage rating: 300 volts Features: ¥The jacket and shield are ÒbondedÓ for ease of removal on automatic strippingequipment Compliances: ¥NEC Article 800 Type CM (UL: 75¡C)¥ UL Style 2092 (UL: 60¡C, 300V)¥Designed to Meet UL 70,000 BTU VerticalTray Flame Test¥CSA CMH (CSA60ûC)¥Passes CSA CMH Flame Test Packaging: ¥ 1000' (305 m) Spools or Reels¥ 500' (152 m) Spools or Reels ¥Other put-ups availableÑconsult Customer Service Multi-Conductor, Foil Shield UL 2092, NEC Type CM (UL) c(UL) CMH C2518 C2519C25212222 22 01 87 / 3 07 / 2 81 6 / 3 0 0 . 0 1 60 . 0 1 60 . 0 1 80 . 4 10 . 4 10 . 4 60 . 0 2 60 . 0 2 80 . 0 2 80 . 6 60 . 7 10 . 7 10 . 1 8 10 . 2 0 10 . 2 2 94 . 6 05 . 1 15 . 8 22 0 . 02 2 . 02 4 . 03 6 . 04 0 . 04 4 . 0 UL STYLE 2092, CM (UL) c(UL) CMH, 300V Polyethylene Insulation, Color Code Chart #1Polypropylene Insulation, Color Code Chart #2*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield C2520 22 27 / 3 0 0 . 0 0 80 . 2 00 . 0 2 00 . 5 10 . 1 3 73 . 4 82 5 . 04 5 . 0 CM (UL) c(UL) CMH, 300V Color Code Chart 1 12 NO. OF COND.COLOR B l a c kN a t u r a l Color Code Chart 2 12 NO. OF COND.COLOR B l a c kR e d CATALOGNUMBERNO. OFCOND.AWGSIZECOND.STRAND.NOM. INSULATION THICKNESSNOM. JACKET THICKNESS NOMINAL O.D.NOM. CAP.* AB 18 Communication & Control Cable, Multi-ConductorElectronics Power-Limited Tray Cable, Foil Shield NEC Type PLTC Product Construction:Conductor: ¥22 thru 12 AWG fully annealed strandedtinned copper per ASTM B-33 Insulation: ¥Premium grade color coded PVC¥Color Code: See chart below Shield: ¥100% Flexfoil ¨ aluminum/polyester,25% overlap foil facing out¥Stranded tinned copper drain wire Jacket: ¥T Applications: ¥Cable tray installations¥Power limited circuits¥Intercom systems¥ Business machines¥Cash registers¥Industrial control systems¥Petrochemical refineries¥Suggested voltage rating: 300 volts¥ Burglar Alarms Features: ¥Sunlight resistant PVC jacket¥Good weather resistance¥UL tray cable rated Compliances: ¥NEC Article 725 Power-Limited Tray Cable(UL: 105¡C, 300V)¥Designed to Meet UL 70,000 BTU VerticalTray Flame Test Packaging: ¥ 1000' (305 m) Spools or Reels¥500' (152 m) Spools or Reels¥Other put-ups availableÑconsult Customer Service C0450 C0451 C0452 C0453 C0454 C0455 C0456 C0457 C0458 C0459C0460232323232322 22 22 02 01 81 81 61 61 41 41 27 / 3 07 / 3 07 / 2 87 / 2 81 6 / 3 01 6 / 3 01 9 / . 0 1 1 71 9 / . 0 1 1 71 9 / . 0 1 4 71 9 / . 0 1 4 71 9 / . 0 1 8 5 0 . 0 1 30 . 0 1 30 . 0 1 30 . 0 1 30 . 0 1 30 . 0 1 30 . 0 1 30 . 0 1 30 . 0 1 30 . 0 1 30 . 0 1 30 . 3 30 . 3 30 . 3 30 . 3 30 . 3 30 . 3 30 . 3 30 . 3 30 . 3 30 . 3 30 . 3 30 . 0 3 70 . 0 3 70 . 0 3 70 . 0 3 70 . 0 3 70 . 0 3 70 . 0 3 70 . 0 3 70 . 0 4 20 . 0 4 20 . 0 4 20 . 9 40 . 9 40 . 9 40 . 9 40 . 9 40 . 9 40 . 9 40 . 9 41 . 0 71 . 0 71 . 0 70 . 1 9 10 . 1 9 90 . 2 0 70 . 2 1 70 . 2 2 70 . 2 3 80 . 2 4 30 . 2 5 50 . 2 8 80 . 2 9 80 . 3 1 54 . 8 55 . 0 55 . 2 65 . 5 15 . 7 76 . 0 46 . 1 76 . 4 87 . 3 27 . 5 78 . 0 04 0 . 53 8 . 04 5 . 54 3 . 05 0 . 04 7 . 05 8 . 55 1 . 56 6 . 05 7 . 07 4 . 07 2 . 56 8 . 08 1 . 57 7 . 09 0 . 08 4 . 51 0 5 . 09 3 . 01 1 8 . 51 0 3 . 01 3 5 . 5 *A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield Color Code Chart 1 23 NO. OF COND.COLOR B l a c kR e dW h i t e CATALOGNUMBERNO. OFCOND.AWGSIZECOND.STRAND.NOM. INSULATION THICKNESSNOM. JACKET THICKNESS NOMINAL O.D.NOM. CAP.* AB 19 ElectronicsCommunication & Control Cable, Multi-Conductor Color Code Chart #1 UL STYLE 2095, CM (UL) c(UL), CSA CMG, 300V C2882C2888222 22 07 / 3 07 / 2 8 0 . 0 1 50 . 0 1 6 0 . 3 80 . 4 10 . 0 3 20 . 0 3 20 . 8 10 . 8 10 . 1 9 70 . 2 1 55 . 0 05 . 4 64 0 . 04 7 . 07 0 . 07 9 . 0 Color Code Chart #1 Product Construction:Conductor: ¥22 thru 16 AWG fully annealed strandedtinned copper per ASTM B-33 Insulation: ¥ Premium grade color coded PVC¥Color Code: See charts below Shield: ¥85% spiral tinned copper Jacket: ¥ PVC, gray¥ Temperature Range: Ð20¡C to +80¡C Applications: ¥Electronic circuits where RF shielding is required¥ Radio transmitters¥Sound systems¥ Recording studios¥Suggested voltage rating: 300 volts Features: ¥Spiral shield allows ease of ÒpigtailsolderingÓ¥ Maximum flexibility Compliances: ¥ NEC Article 800 Type CM (UL: 75¡C)¥ UL Style 2095 (UL: 80¡C, 300V)¥ CSA CMG (CSA: 60¡C)¥Designed to Meet UL 70,000 BTU VerticalTray Flame Test¥ Passes CSA CMG Flame Test Packaging: ¥ 1000' (305 m) Spools or Reels¥ 500' (152 m) Spools or Reels¥Other put-ups availableÑconsult Customer Service Multi-Conductor, Spiral Shield UL 2095, NEC Type CL2 and CM (UL) c(UL), CSA CMG CM (UL) c(UL), CSA CMG, 300V C2892C2895221 81 61 6 / 3 01 9 / . 0 1 1 7 0 . 0 1 60 . 0 1 6 0 . 4 10 . 4 10 . 0 3 20 . 0 3 20 . 8 10 . 8 10 . 2 4 30 . 2 6 56 . 1 76 . 7 55 3 . 05 7 . 09 2 . 09 8 . 0 CL2/CM (UL) c(UL), CSA CMG, 300V C1335 C1337 C1341C276834632 22 22 21 87 / 3 07 / 3 07 / 3 01 6 / 3 0 0 . 0 1 50 . 0 1 50 . 0 1 50 . 0 1 6 0 . 3 80 . 3 80 . 3 80 . 4 10 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 8 10 . 8 10 . 8 10 . 8 10 . 2 0 60 . 2 2 20 . 2 5 70 . 2 5 65 . 2 35 . 6 46 . 5 36 . 5 03 7 . 03 5 . 03 4 . 04 3 . 06 6 . 06 2 . 06 0 . 07 8 . 0 Color Code Chart #2*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield Color Code Chart 1 1 2 3 4 56 NO. OF COND.COLOR B l a c kR e dW h i t eG re e nYe l l o wB l u e Color Code Chart 2 C2892 C2895 CATALOGNUMBERCONDUCTORCOLOR 1212W h i t eR e dW h i t eB l a c k CATALOGNUMBERNO. OFCOND.AWGSIZECOND.STRAND.NOM. INSULATION THICKNESSNOM. JACKET THICKNESS NOMINAL O.D.NOM. CAP.* AB 20 Communication & Control Cable, Multi-ConductorElectronics Multi-Conductor, Braid Shield UL 2095, NEC Type CM (UL) c(UL), CSA CMG Product Construction:Conductor: ¥22 AWG fully annealed solid or strandedtinned copper per ASTM B-33 Insulation: ¥Premium grade color coded PVC¥ Color Code: See chart below Shield: ¥ 88% tinned copper braid¥Stranded or solid tinned copper drain wire Jacket: ¥T Applications: ¥Electronic circuits where RF shielding is required¥Radio transmitters¥ Sound systems¥Recording studios¥ Good flexibility¥Excellent shielding for noise reduction¥Suggested voltage rating: 300 volts Compliances: ¥ NEC Article 800 Type CM (UL: 75¡C)¥UL Style 2095 (UL: 80¡C, 300V)¥Designed to Meet UL 70,000 BTU VerticalTray Flame Test¥CSA CMG (CSA: 60¡C)¥Passes CSA CMG Flame Test Packaging: ¥1000' (305 m) Spools¥500' (152 m) Spools¥Other put-ups availableÑconsult Customer Service C2676C2677222 22 2S o l i d7 / 3 0 0 . 0 1 50 . 0 1 5 0 . 3 80 . 3 80 . 0 3 20 . 0 3 20 . 8 10 . 8 10 . 2 0 90 . 2 1 15 . 3 15 . 3 64 8 . 04 9 . 08 5 . 08 6 . 0 *A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield Color Code Chart 12 NO. OF COND.COLOR B l a c kR e d CATALOGNUMBERNO. OFCOND.AWGSIZECOND.STRAND.NOM. INSULATION THICKNESSNOM. JACKET THICKNESS NOMINAL O.D.NOM. CAP.* pF/ftINCHESmmINCHESmmINCHESmmAB 21 ElectronicsCommunication & Control Cable, Multi-Conductor Product Construction:Conductor: ¥22 thru 18 AWG fully annealed strandedtinned copper per ASTM B-33 Insulation: ¥ Premium grade color coded PVC¥Color Code: See chart below Shield: ¥ 75% tinned copper braid Jacket: ¥ PVC, gray¥ Temperature Range: Ð20¡C to +80¡C Applications: ¥Electronic circuits where RF shielding is required¥ Radio transmitters¥Sound systems¥ Recording studios¥ Provides good flexibility¥ Excellent shielding for noise reduction¥ Suggested voltage rating: 300 volts Compliances: ¥ NEC Article 800 Type CM (UL: 75¡C)¥ UL Style 2095 (UL: 80¡C, 300V)¥Designed to Meet UL 70,000 BTU VerticalTray Flame Test¥ CSA CMG (CSA: 60¡C)¥ Passes CSA CMG Flame Test Packaging: ¥ 1000' (305 m) Spools¥500' (152 m) Spools¥Other put-ups availableÑconsult Customer Service Multi-Conductor, Braid Shield UL 2095, NEC Type CM (UL) c(UL), CSA CMG C2679 C2678 C2680 C2681 C1332 C2683 C2686 C2687C26882342342342 22 22 22 02 02 01 81 81 87 / 3 07 / 3 07 / 3 07 / 2 87 / 2 87 / 2 81 6 / 3 01 6 / 3 01 6 / 3 0 0 . 0 1 50 . 0 1 50 . 0 1 50 . 0 1 60 . 0 1 60 . 0 1 60 . 0 1 60 . 0 1 60 . 0 1 6 0 . 3 80 . 3 80 . 3 80 . 4 10 . 4 10 . 4 10 . 4 10 . 4 10 . 4 10 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 0 3 20 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 8 10 . 2 1 20 . 2 2 10 . 2 3 70 . 2 3 00 . 2 4 00 . 2 5 90 . 2 5 20 . 2 6 40 . 2 8 65 . 3 85 . 6 16 . 0 25 . 8 46 . 1 06 . 5 86 . 4 06 . 7 17 . 2 64 1 . 03 7 . 03 7 . 04 2 . 04 2 . 03 9 . 04 7 . 04 3 . 04 3 . 07 3 . 06 7 . 06 7 . 07 6 . 07 6 . 07 0 . 08 5 . 07 8 . 07 8 . 0 *A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield Color Code Chart 1 2 34 NO. OF COND.COLOR B l a c kR e dW h i t eG re e n CATALOGNUMBERNO. OFCOND.AWGSIZECOND.STRAND.NOM. INSULATION THICKNESSNOM. JACKET THICKNESS NOMINAL O.D.NOM. CAP.* AB 22 Communication & Control Cable, Multi-ConductorElectronics Multi-Conductor, Braid Shield MIL-W-16878 Type B Product Construction:Conductor: ¥28 AWG fully annealed stranded tinnedcopper per ASTM B-33 Insulation: ¥Premium grade color coded S-R PVC perMIL-W-16878 Type B¥Color Code: See chart below Shield: ¥90% tinned copper braid Jacket: ¥T Applications: ¥Electronic circuits where RF shielding is required¥Remote control for studio equipment¥Sound systems¥Provides good flexibility¥Excellent shielding for noise reduction¥Suggested voltage rating: 600 volts¥ Non QPL Packaging: ¥1000' (305 m) Spools or Reels¥500' (152 m) Spools or Reels¥Other put-ups availableÑconsult Customer Service C6500 C6501 C6502 C6503 C6504 C6505 C6506 C6507C6508234681 01 21 52 02 82 82 82 82 82 82 82 82 87 / 3 67 / 3 67 / 3 67 / 3 67 / 3 67 / 3 67 / 3 67 / 3 67 / 3 6 0.011 0 . 2 80 . 2 80 . 2 80 . 2 80 . 2 80 . 2 80 . 2 80 . 2 80 . 2 80 . 0 1 60 . 0 1 60 . 0 1 60 . 0 1 90 . 0 2 10 . 0 2 10 . 0 2 10 . 0 2 10 . 0 2 10 . 4 10 . 4 10 . 4 10 . 4 80 . 5 30 . 5 30 . 5 30 . 5 30 . 5 30 . 1 3 00 . 1 3 50 . 1 4 50 . 1 7 20 . 1 8 70 . 2 1 20 . 2 1 70 . 2 3 70 . 2 8 93 . 3 03 . 4 33 . 6 84 . 3 74 . 7 55 . 3 85 . 5 16 . 0 27 . 3 43 0 . 03 0 . 03 0 . 03 0 . 02 2 . 02 2 . 02 2 . 02 2 . 02 2 . 05 4 . 05 4 . 05 4 . 05 4 . 04 0 . 04 0 . 04 0 . 04 0 . 04 0 . 0 *A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield Color Code Chart 1 2 3 4 5 67 NO. OFCOND.COLOR B l a c kW h i t eR e dG re e nO r a n g eB l u eW h i t e / B l a c k891011121314 NO. OFCOND.COLORNO. OFCOND.COLOR R e d / B l a c kG re e n / B l a c kO r a n g e / B l a c kB l u e / B l a c kB l a c k / W h i t eR e d / W h i t eG re e n / W h i t e 15 16 17 18 1920B l u e / W h i t eB l a c k / R e dW h i t e / R e dO r a n g e / R e dB l u e / R e dR e d / G re e n CATALOGNUMBERNO. OFCOND.AWGSIZECOND.STRAND.NOM. INSULATION THICKNESSNOM. JACKET THICKNESS NOMINAL O.D.NOM. CAP.* AB 23 ElectronicsCommunication & Control Cable, Multi-Conductor Product Construction:Conductor: ¥20 AWG fully annealed stranded tinnedcopper per ASTM B-33 Insulation: ¥ Premium grade color coded polyethylene¥Color Code: See chart below Shield: ¥80% tinned copper braid Jacket: ¥T Applications: ¥V Features: ¥ Low capacitance¥Lightweight¥ Excellent shielding for noise reduction Compliances: ¥UL Style 2092 (UL: 80¡C, 300V)¥UL Style 2093 (UL: 80¡C, 300V)¥UL Style 2094 (UL: 80¡C, 300V)¥Designed to Meet UL VW-1 Vertical WireFlame Test Packaging: ¥ 1000' (305 m) Spools or Reels¥500' (152 m) Spools or Reels¥Other put-ups availableÑconsult Customer Service Multi-Conductor, Braid Shield UL 2092, 2093, 2094 C1642 C1643 C1644 C1645C1646234562 02 02 02 02 02 6 / 3 42 6 / 3 42 6 / 3 42 6 / 3 42 6 / 3 4 0 . 0 1 50 . 0 1 50 . 0 1 50 . 0 1 50 . 0 1 5 0 . 3 80 . 3 80 . 3 80 . 3 80 . 3 80 . 0 2 90 . 0 2 90 . 0 2 90 . 0 2 90 . 0 2 90 . 7 40 . 7 40 . 7 40 . 7 40 . 7 40 . 2 2 60 . 2 3 60 . 2 5 50 . 2 7 40 . 2 9 45 . 7 45 . 9 96 . 4 86 . 9 67 . 4 82 4 . 02 2 . 02 2 . 02 2 . 02 1 . 04 4 . 04 0 . 04 0 . 04 0 . 03 7 . 0 *A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield Color Code Chart 1 2 3 4 56 NO. OF COND.COLOR B l a c kW h i t eR e dG re e nYe l l o wB l u e UL Style Chart 2092 2093 2094 20942094 STYLECATALOGNUMBER C 1 6 4 2C 1 6 4 3C 1 6 4 4C 1 6 4 5C 1 6 4 6 CATALOGNUMBERNO. OFCOND.AWGSIZECOND.STRAND.NOM. INSULATION THICKNESSNOM. JACKET THICKNESS NOMINAL O.D.NOM. CAP.* AB 24 Communication & Control Cable, Multi-ConductorElectronics Multi-Conductor, Foil/Braid Shield UL 2094, NEC Type CL2 Product Construction:Conductor: ¥20 AWG fully annealed stranded tinnedcopper per ASTM B-33 Insulation: ¥Premium grade color coded polyethylene¥Color Code: See chart below Shield: ¥100% Flexfoil ¨ aluminum/polyester,25% overlap, foil facing out ¥80% tinned copper braid Jacket: ¥PVC, gray¥ Temperature Range: Ð20¡C to +60¡C Applications: ¥V Features: ¥Low capacitance¥Lightweight¥Excellent shielding for noise reduction Compliances: ¥NEC Article 725 Type CL2 (UL: 75¡C)¥UL Style 2094 (UL: 60¡C, 300V)¥Designed to Meet UL 70,000 BTU VerticalTray Flame Test Packaging: ¥1000' (305 m) Spools¥500' (152 m) Spools¥Other put-ups availableÑconsult Customer Service C164882 02 6 / 3 4 0 . 0 1 5 0 . 3 80 . 0 2 90 . 7 40 . 3 1 68 . 0 32 1 . 03 7 . 0 *A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield 1 2 34B l a c kW h i t eR e dG re e n 5 6 Color Code Chart NO. OF COND.COLOR NO. OF COND. COLOR CATALOGNUMBERNO. OFCOND.AWGSIZECOND.STRAND.NOM. INSULATION THICKNESSNOM. JACKET THICKNESS NOMINAL O.D.NOM. CAP.* AB 25 ElectronicsCommunication & Control Cable, Multi-Conductor Product Construction:Conductor: ¥20 AWG fully annealed stranded tinnedcopper per ASTM B-33 Insulation: ¥ Premium grade color coded rubber¥ Color Code: See chart below Shield: ¥80% tinned copper braid Jacket: ¥Rubber, black¥ Temperature Range: Ð20¡C to +60¡C Applications: ¥Control circuits¥Broadcast and studio applications¥ Audio interconnects¥Suggested voltage rating: 300 volts Features: ¥ Impact and abrasion resistant¥Stranded conductors for superior flexibility Packaging: ¥1000' (305 m) Spools or Reels¥500' (152 m) Spools or Reels¥Other put-ups availableÑconsult Customer Service Multi-Conductor, Rubber, Braid Shield C1302 C1304 C1305 C1308 C1310 C1312C131323456782 02 02 02 02 02 02 02 6 / 3 42 6 / 3 42 6 / 3 42 6 / 3 42 6 / 3 42 6 / 3 42 6 / 3 4 0 . 0 2 00 . 0 2 00 . 0 2 00 . 0 2 00 . 0 2 00 . 0 2 00 . 0 2 00 . 5 10 . 5 10 . 5 10 . 5 10 . 5 10 . 5 10 . 5 10 . 0 3 50 . 0 3 50 . 0 3 50 . 0 3 50 . 0 3 50 . 0 3 50 . 0 3 50 . 8 90 . 8 90 . 8 90 . 8 90 . 8 90 . 8 90 . 8 90 . 2 7 00 . 2 8 50 . 3 0 50 . 3 3 00 . 3 4 50 . 3 6 00 . 3 8 56 . 8 67 . 2 47 . 7 58 . 3 88 . 7 69 . 1 49 . 7 8 1 2 34B l a c kW h i t eR e dG re e n 5 6 Color Code Chart NO. OF COND.COLOR NO. OF COND. COLOR CATALOGNUMBERNO. OFCOND.AWGSIZECOND.STRAND.NOM. INSULATION THICKNESSNOM. JACKET THICKNESS NOMINAL O.D.INCHESmmINCHESmmINCHESmm 26 Communication & Control Cable, Multi-ConductorElectronics Multi-Conductor, Carolprene ¨ , Braid Shield Product Construction:Conductor: ¥18 thru 14 AWG fully annealed strandedtinned copper per ASTM B-33 Insulation: ¥Premium grade color coded rubber¥Color Code: See chart below Shield: ¥80% tinned copper braid Jacket: ¥Carolprene ¨ ¥T Applications: ¥Control circuits¥Broadcast and studio applications¥Audio interconnects¥Suggested voltage rating: 300 volts Features: ¥ Impact and abrasion resistant¥Stranded conductors for superior flexibility¥Designed to Meet UL VW-1 Vertical WireFlame Test Packaging: ¥1000' (305 m) Spools or Reels¥500' (152 m) Spools or Reels¥Other put-ups availableÑconsult Customer Service C1202 C1203 C1204 C1206 C1208 C1210 C1212 C1602 C1603 C1604 C1606 C1608 C1612C1614234681 01 223468241 81 81 81 81 81 81 81 61 61 61 61 61 41 44 1 / 3 44 1 / 3 44 1 / 3 44 1 / 3 44 1 / 3 44 1 / 3 44 1 / 3 46 5 / 3 46 5 / 3 46 5 / 3 46 5 / 3 46 5 / 3 44 1 / 3 04 1 / 3 0 0.425 1 2 3 4 Color Code Chart NO. OF COND.COLOR NO. OF COND. COLOR CATALOGNUMBERNO. OFCOND.AWGSIZECOND.STRAND.NOM. INSULATION THICKNESSNOM. JACKET THICKNESS NOMINAL O.D.INCHESmmINCHESmmINCHESmm