Boris Sursky LEED AP BD C 7863152050 skymiamidadegov The eRoofing Permitting System is the WINNER of the prestigious NATIONAL ROOFING CONTRACTORS ASSOCIATION 2003 ID: 699490

system roof noa roofing roof system roofing noa tile required click attachment note underlayment slope product permitting epermitting permit

Share:

Link:

Embed:

Download Presentation from below link

Download Presentation The PPT/PDF document "ePermitting Roofing System" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

Slide1
Slide2

ePermitting

Roofing System

Boris Sursky LEED AP BD + C

786-315-2050 sky@miamidade.govSlide3

The

e-Roofing Permitting System

is the

WINNER

of the prestigious NATIONAL ROOFING CONTRACTORS ASSOCIATION 2003 GOLD CIRCLE AWARD for service to industry.Slide4

The

e-Roofing Permitting System

is the

WINNER

of the

2004 NATIONAL ASSOCIATIONS OF COUNTIES AWARD FOR INTEGRATING PROCESSES AND SERVICE: ROOFING/STORM PANEL PERMITTING AND SERVICES SYSTEMSlide5

The

e-Roofing Permitting System

provides progressive and improved customer service through the use of advanced technology.Slide6

The

e-Roofing Permitting System

is an revolutionary permitting application process, with tens of thousands of Roofing permits issued since 2004.Slide7

The

e-Roofing Permitting System

was put to the test after Hurricane

Wilma which occurred

in

2005, when over 12,000 e-Roofing permits were issued in a 12 month period using this system.Slide8
Slide9

CLICK HERESlide10

CLICK HERESlide11

CLICK HERESlide12

CLICK HERESlide13

CLICK HERESlide14

CLICK HERESlide15

ENTER TRADESMAN NUMBERSlide16

Contact Contractor’s Section for assistance

with Tradesman Number.Slide17
Slide18

CREATE USER PROFILESlide19

CLICK HERESlide20
Slide21
Slide22
Slide23

CLICK HERESlide24

Enter:

Roofing (CCC) Contractor License

NumberSlide25
Slide26

2 units required for duplexesSlide27

Use total ft

²

“NOT 2 Roofing Squares”

CL

IC

K HERESlide28
Slide29

Select Low Slope ManufacturerSlide30
Slide31

Do Not Use FractionsSlide32
Slide33
Slide34
Slide35
Slide36
Slide37

Minimum

2/12” ROOF SLOPE

required for shinglesSlide38

ROOF MEAN

HEIGHTS

CAN NOT EXCEDE 33 FT.Slide39

Note: Prescriptive

fastener spacingSlide40

Note: Online Review was not

approved. This happens after

2 code related rejections

An example of a code related rejection, would be an incorrect roof slope or roof mean height.Slide41
Slide42
Slide43
Slide44

All Dispositions required to be approved prior to paying for permitSlide45

Note: Provide a completed Owner’s Notification Form at the jobsite to be collected by the inspector and submitted to Micro-Film as part of the permit record.Slide46
Slide47

Print completed roofing application forms for jobsite inspectionsSlide48

ePermitting

NO NO’s

Use total ft² on permit application, do not use roofing squares (1=100 s.f.)

No Florida Product Approvals allowed, only use current Miami-Dade County Product Approvals with the ePermitting SystemSlide49

ePermitting

NO NO’s

Do not use fractions when inputting data, use only decimal numbers

Use correct slope for specific roof system types, for example a minimum 4/12 slope is required for mechanically attached tilesSlide50

ePermitting

NO NO’s

NO CHANGES CAN BE MADE TO the “

ePermitting System generated Uniform Permit forms.Changes to system generated forms require a permit revision.Slide51

ePermitting

NO NO’s

DO NOT SHARE YOUR PASSWORD TO ACCESS THE “

ePermitting” SYSTEMWITH ANY ONE YOU DO NOT TRUST!PERMITS CAN BE OBTAINED WITHOUT YOUR KNOWLEDGE!Slide52

REQUIRED DOCUMENTS

FOR JOB SITE INSPECTION

A completed Section 1524 Owner’s Notification Form to be collected by Inspector and placed in Micro-FilmSlide53

REQUIRED DOCUMENTS

FOR JOB SITE INSPECTION

Completed Section A & B page including a roof plan diagram. Total roof area to be field verified by inspector & shall match paid permit fees.

The completed roof plan diagram shall included dimensions, roof sections, levels and roof types.Slide54

REQUIRED DOCUMENTS

FOR JOB SITE INSPECTION

Printed copy of the “

ePermitting” system generated Uniform Roof Permit Form for the types of roof systems to be installed.Category 92 Low Slope BURCategory 95 ShinglesCategory 107 TileSlide55

REQUIRED DOCUMENTS

FOR JOB SITE INSPECTION

One copy of the Miami-Dade NOA Product Approval for the proposed roof system(s) to be installedSlide56

REQUIRED DOCUMENTS

FOR JOB SITE INSPECTION

Low Slope BUR NOA Approval including

Cover Page, System Page(s), Limitation Page(s)Class “A” Fire Directory Listing for the Low Slope BURSlide57

REQUIRED DOCUMENTS

FOR JOB SITE INSPECTION

Tile NOA Product Approval

Tile Underlayment NOA Product ApprovalTile Adhesive or Mortar NOA Product ApprovalSlide58

“ePermitting”

Improvements

CATEGORY 107 TILE ROOF SYSTEMSSlide59

New Tile Underlayment Selections

Prescriptive 30/90 hot mopped

Modified Bitumen hot mopped with a required NOA Product Approval for tile underlayment

Self Adhered Modified Bitumen with a required NOA Product Approval for tile underlaymentSlide60
Slide61

Select Tile Mechanical Attachment MethodSlide62

Select Mortar Attachment TypeSlide63

Select Adhesive Attachment TypeSlide64

Adhesive Type Selected,

Note Exposure Category Selected

EXPOSURE CATEGORY D

IS TYPICALLY OCEAN LINESlide65

Select Roof Deck TypeSlide66

Select Base Sheet TypeSlide67

Prescriptive Tile Underlayment

SelectedSlide68

Modified Bitumen Hot Mopped Tile UnderlaymentSlide69

Self Adhered (S/A) UnderlaymentSlide70

I Agree StatementSlide71

SAMPLE NOA LIMITATIONSSlide72

SAMPLE NOA LIMITATIONSSlide73

SAMPLE NOA LIMITATIONSSlide74

SAMPLE NOA LIMITATIONSSlide75

Tile Roof System Shall comply with RAS 118, 119, 120

CLICK HERESlide76

Self Adhered Underlayment Selected

Note: Yes “I AGREE”

STATEMENT SELECTEDSlide77

Note: Attachment MethodSlide78

Note: That the calculated attachment

resistance in P3 is greater than

attachment resistance found in the

NOASlide79

Note: Attachment MethodSlide80

Note: That the calculated attachment

resistance for all roof zones are LESS

than the attachment resistance found

in the Tile NOA.Slide81

Submit Review if Application is Complete

CLICK HERESlide82

Approved Application