ANK ANK Heating  and cooling ANK ANK Heating  and cooling

ANK ANK Heating and cooling - PowerPoint Presentation

robaut
robaut . @robaut
Follow
349 views
Uploaded On 2020-08-28

ANK ANK Heating and cooling - PPT Presentation

High efficiency Refrigerant R410A 3 unit sizes with power supply 220160 Standards complies with UL Max water out 140 F 131 F ANK50 Chiiled water as low as 21F Heating between 4F and 107F ID: 809595

water ank unit control ank water control unit details air heating features circuit temperature cooling hydraulic set remote switch

Share:

Link:

Embed:

Download Presentation from below link

Download The PPT/PDF document "ANK ANK Heating and cooling" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.


Presentation Transcript

Slide1

ANK

ANK

Slide2

Heating

and cooling

High efficiency

Refrigerant:

R410A

3 unit sizes with power supply 220/1/60

Standards: complies with UL

Max water out 140˚F (131

˚F ANK50)

Chiiled water as low as 21˚F

Heating between -4˚F and 107˚F

Cooling between 21˚F and 114˚FETL approved

ANK Main Features

ANK Features

Slide3

ANK Features

Reversible heat pumps Air/water

Optimized for heating, OD installation

Cooling

30,000 up

to

49,000 BTU

Heating 37,670 up to 57,598 BTU

H standard version (no water pump/tank)

HP version with water pump built in

HA version with hydronic kit built in

Heating ext. working limit up to -4°FHDW production from -4˚F up to

107°F

Slide4

ANK Characteristics

Electric

box with

easy access

Condensate drip tray and optional electric heater on the bottom under the

coil for northern climatesEasy

maintenance with the electric box swinging out on a hinge for easy access to all components

Slide5

ANK Dimensions

Cooling (AHRI Conditions)

Outlet

water temperature 6.7˚C /

44.6˚FFlow rate 0,043l/s per kWExternal temperature

35˚C / 95˚F

Nominal Reference AHRI Conditions

Heating (AHRI Conditions)Water

input temperature 104˚F Output water temperature

113˚F

External

air temperature d.b./w.b. 44.6-42.8˚F / 7-6˚C Δt 10.01˚F / 5˚C

Slide6

ANK Working Limits

Heating

Cooling

Air

Water

Air

Water

-4°F

122°F

104°F

17.6°F

14°F

140°F

104°F

64.4°F

107°F

132.8°F

114°F

39.5°F

114°F

50°F

between

between

Slide7

ANK Range

ANK Dimensions

Slide8

ANK***H

units are supplied with water filter, flow switch and safety switch

ANK***HP

units receive all of the above and a pump and expansion tank

ANK***HA

units receive all of above and internal buffer tank as well

HA includes pump and tank

HP includes pump

H standard

New Frame of the Version with Tank

(Available from 09/10)

Slide9

New Frame of the Version with Tank

(Available from 09/10)

Slide10

Set Point Compensation Logic

Set point compensation according to the ambient temperature, to change set and performance when we need and save energy in the same time

Slide11

ANK Operation Limits

Slide12

ANK Operation Limits

Slide13

ANK Operation Limits

Slide14

ANK Installation Technical Spaces

HA frame

H – HP frame

Support surface and leave enough space for correct air circulation and to allow maintenance

Slide15

Components standard mounted and position

Water Filter

mesh 500µm

Flow switch

Water pump

Wilo

TOP-S 125-24

Expansion vessel

pressured 22 PSI

Relief water valve 87 PSI

Water pipe connection: manual air vent

pipe connected behind coming from highest unit point

ANK Hydraulic Features

Slide16

ANK Hydraulic Features

Water Features:

Minimum Water Content:

ANK

030

045

050

Number compressor

1

1

1Recommended minimum water content

gal/ton9.3

9.39.3

Slide17

ANK Hydraulic Features

Water Pipes Connections:

H –HP version

HA version

Slide18

ANK Hydraulic Features

External hydraulic circuit suggestion: H version

Slide19

ANK Hydraulic Features

External hydraulic circuit suggestion: HP version

Slide20

ANK Hydraulic Features

External hydraulic circuit suggestion: HA version

Slide21

Unit will be protected with an external power line switch IL, connected to power line by a cable (Line, Neutral earth) with section have to be appropriately calculated and fixed on IG unit main

switch

Voltage line tollerance+/-10

%

The use of IL with suitable cut off and differential protection is mandatory as the earth cable

ANK045HA°°°°5

ANK Electrical Features

Slide22

ANK Electrical Features

Auxiliary Electrical Inputs:

Remote start/stop IA control

Remote cool/heat C/F control

Remote alarm AE indication

Remote DHW-TWS call control Remote force-off TRA control

Remote EH-Boiler RCR control

Aux. connection here

Terminal plugged here

Slide23

ANK Wiring Diagram

Slide24

ANK Wiring Diagram

Slide25

ANK Wiring Diagram

Slide26

ANK Wiring Diagram

Slide27

PR3 Remote S

imple Panel

Max remote distance 150 mt

Cable 7 poles, min section per each wires 0.5 mm

2, 20 AWGConnection

on unit internal green terminal

Commands

Remote unit ON-OFF

Heating-cooling selection

Alarms reset by fast on-off button selection (3 x hour)

ANK Accessories

Slide28

ANK Accessories

MODU-485A

: RS-485 interface card for supervisor system

MODBUS RTU protocol

8bits, parity none, 2 stop bits

To enable the communication go to INSTALLER menù psw 030 and to set:

Parameter J = supervisor address requested

Parameter L = baud rate (0=9600, 1=19200, 2=38400)

Parameter N = 1 to enable remote writings (setpoints, on-off, reset

alarms...)

Slide29

VT

: antivibration kit fixed

under unit basement to stop vibration

transmission

ANK Accessories

Slide30

ANK Accessories

AERWEB300

: To log and monitor unit datas

via Lan or GPRS connection

It is possible to control max 6 (aerweb300-6) or 18 (aerweb300-18)

Slide31

ANK Accessories

Slide32

ANK Accessories

MULTICONTROL

:

Can control up to 4 machines

equipped with moducontrol and RS485 cards installed in the same hydraulic system

Control

Chillers, according to the system capacity demand, can be driven by load, delta water temperature or in homogenous mode

Can control starting, stopping and separated operating setpoints (DHW and heating/cooling) for a maximum four units in autonomous mode or as slaves in a same system

Can be used also as remote control where the controls and units information are centralized

Slide33

ANK Accessories

Electric heater

Electric heater and drip trail

KRB:

will be soonest available EH or EH plus drip trail to help the drainage

Slide34

ANK MODUCONTROL Controller

Unit Terminal

Menus selector under

psw

Readings values

Start-stop selector

Press 3”

Parameter index

Alarms record selected

Alarms record

Settingsmenus call

Cooling led

Heating

dhw

led

Scrolling keys

Compressor call

Alarm led

Unit status led

Slide35

ANK MODUCONTROL Controller

Unit Terminal Keys Meaning

Slide36

ANK MODUCONTROL Controller

ANK dip setting:

1 - ON heat pump unit

2 – ON defrost by reversing cycle

3 – ON antifreeze set point unblocked4 – ON capacity control not activated

5 – ON safety steps not available6 – ON low water content not activated7 – OFF fan speed control not present

8 – OFF9 – OFF

10 – OFF11 – OFF12 – OFF

Trasducers configuration1 – OFF 2 - OFF

5 temperature sensors

2 trasducers

Outlet water regulation PISmart defrosting cyclesCompensation set pointDomestic hot water application with dedicated set point

Self adaptive working for plants with low water contentSmart managing of electric heaters

Slide37

ANK Unit Commissioning

Checks Before to Start the Unit:

Unit placement: technical spaces respected

suitable support surface

Unit status: check unit status (no visible damages)

no visible oil leaks (regrigerant lost)Water circuit: check water connections respected

circuit water pressured all shut off valves opened

air evacuated water connections tightened (no leak)

Electrical : check section power cable earth cable connection IL power line switch selection

auxiliary inputs connected

all cables well tighneted

voltage line tollerance +/-10%

Unit has to be powered 24 hours before to warm compressor oil turning on main unit switch and checking that unit is switched off (no green led)

Slide38

ANK Unit Commissioning Setting

Slide39

ANK Unit Commissioning Settings

Resistance Management Menu psw 001

Slide40

ANK Unit Commissioning Settings

Slide41

ANK Unit Commissioning

Start Up

After

checks and settings go through READING menu

to verify accurate values read

Slide42

ANK Unit Commissioning

Slide43

ANK Unit Commissioning

Slide44

ANK Refrigerant Circuit

Slide45

ANK Refrigerant Circuit

Calibrated orifice

Liquid separator

Expansion vessel

Liquid accumulator

4 way valve

powered in cooling

Air exchanger distributor

Expansion valve

Dry filter

High pressure switch

609 PSI

Water filter

Transducers

Flow switch

Slide46

ANK Control Details

Slide47

ANK Control Details

Slide48

ANK Control Details

Slide49

ANK Control Details

When:

Decrease of suction pressure by more than 5.8 PSI

Outdoor temperature below 50˚F, coil temperature below 39˚F

Leaving water temperature is more than 86˚F (to reach confort quickly in cold starts)

Defrost end by suction pressure rise or maximum time

How:

Reverse cycle: under severe condition:

If the defrost is called in a shorter time for 3 times

If the suction pressure is less than 40.6 PSI

ANK Control Details - Defrost

Slide50

ANK Control Details

Slide51

ANK Control Details

Slide52

ANK Control Details

Slide53

ANK Control Details

Slide54

ANK Control Details – Loads Defrost Management

Slide55

ANK Control Details – Smart Starter Management

ANK machines are smart starter standard equipped

Can limit inrush currents to 40AACrms upon applying the control signal

Spoft starting is achieved within a 600ms interval

Managed by

Slide56

ANK Control Details –

Fan Speed Controller

Slide57

ANK Control Details –

Fan Speed Controller

Set HP

261PSI

Set HP + differential

Cooling Mode

Slide58

ANK Control Details –

Fan Speed Controller

Heating Mode

Slide59

ANK Control Details –

Screensavers

A screen saver can be inserted by index INSTALLER menu psw 030

Selection 1 Selection 2

Slide60

ANK Troubleshooting

FACTORY psw 125

Alarm Summary Table

Slide61

ANK Troubleshooting

Slide62

ANK Troubleshooting

Slide63

ANK Troubleshooting

AL001: CIRCUIT BREAKER

MTCCP contact opened or switched off

AL003: HIGH PRESSURE by HP SWITCH

AL012 : HIGH PRESSURE by HP TRASDUCERS

IN COOLING: fans off, air exchanger dirty, devices out of order, installation

IN HEATING: out of working limit, no enough water flow,gas charge, exp valve devices

AL004 : FLOW SWITCH

Water filter, air in the system, pump out, flowswitch out, shutt off valves closed, high pressure drops

AL008 : ANTIFREEZE

Water filter, low water set point, wrong antifreeze set point, low water volume

AL010 : HIGH DISCHARGE TEMPERATURE

Working limit, refrigerant charge, expansion valve, compressor

AL015 : LOW PRESSURE by TRASDUCERS

Working limit, refrigerant charge, fans out, air exchanger dirty, installation, device

Slide64

ANK Maintenance

Periodical maintenance for correct functioning and long term duration to prevent failures

Hydraulic

Circuit:

Water

circuit filling, clean water filter, bleed air, pipes insulation, glycol check, water flow control

Electrical Circuit:

Safeties

efficiency test, voltage power supply control, loads absorption, connections tightness, cables quality, oil compressor and antifreeze heaters

Refrigerant Circuit:

Working parameters control HP, BP, Sh, Sc, safeties efficiency test, refrigerant pipes installation

Mechanical

Checks:

Screws tightning,

state of structure

Slide65