Download The PPT/PDF document "ANK ANK Heating and cooling" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.
Slide1
ANK
ANK
Slide2Heating
and cooling
High efficiency
Refrigerant:
R410A
3 unit sizes with power supply 220/1/60
Standards: complies with UL
Max water out 140˚F (131
˚F ANK50)
Chiiled water as low as 21˚F
Heating between -4˚F and 107˚F
Cooling between 21˚F and 114˚FETL approved
ANK Main Features
ANK Features
Slide3ANK Features
Reversible heat pumps Air/water
Optimized for heating, OD installation
Cooling
30,000 up
to
49,000 BTU
Heating 37,670 up to 57,598 BTU
H standard version (no water pump/tank)
HP version with water pump built in
HA version with hydronic kit built in
Heating ext. working limit up to -4°FHDW production from -4˚F up to
107°F
Slide4ANK Characteristics
Electric
box with
easy access
Condensate drip tray and optional electric heater on the bottom under the
coil for northern climatesEasy
maintenance with the electric box swinging out on a hinge for easy access to all components
Slide5ANK Dimensions
Cooling (AHRI Conditions)
Outlet
water temperature 6.7˚C /
44.6˚FFlow rate 0,043l/s per kWExternal temperature
35˚C / 95˚F
Nominal Reference AHRI Conditions
Heating (AHRI Conditions)Water
input temperature 104˚F Output water temperature
113˚F
External
air temperature d.b./w.b. 44.6-42.8˚F / 7-6˚C Δt 10.01˚F / 5˚C
Slide6ANK Working Limits
Heating
Cooling
Air
Water
Air
Water
-4°F
122°F
104°F
17.6°F
14°F
140°F
104°F
64.4°F
107°F
132.8°F
114°F
39.5°F
114°F
50°F
between
between
Slide7ANK Range
ANK Dimensions
Slide8ANK***H
units are supplied with water filter, flow switch and safety switch
ANK***HP
units receive all of the above and a pump and expansion tank
ANK***HA
units receive all of above and internal buffer tank as well
HA includes pump and tank
HP includes pump
H standard
New Frame of the Version with Tank
(Available from 09/10)
Slide9New Frame of the Version with Tank
(Available from 09/10)
Slide10Set Point Compensation Logic
Set point compensation according to the ambient temperature, to change set and performance when we need and save energy in the same time
ANK Operation Limits
Slide12ANK Operation Limits
Slide13ANK Operation Limits
Slide14ANK Installation Technical Spaces
HA frame
H – HP frame
Support surface and leave enough space for correct air circulation and to allow maintenance
Slide15Components standard mounted and position
Water Filter
mesh 500µm
Flow switch
Water pump
Wilo
TOP-S 125-24
Expansion vessel
pressured 22 PSI
Relief water valve 87 PSI
Water pipe connection: manual air vent
pipe connected behind coming from highest unit point
ANK Hydraulic Features
Slide16ANK Hydraulic Features
Water Features:
Minimum Water Content:
ANK
030
045
050
Number compressor
n˚
1
1
1Recommended minimum water content
gal/ton9.3
9.39.3
Slide17ANK Hydraulic Features
Water Pipes Connections:
H –HP version
HA version
Slide18ANK Hydraulic Features
External hydraulic circuit suggestion: H version
Slide19ANK Hydraulic Features
External hydraulic circuit suggestion: HP version
Slide20ANK Hydraulic Features
External hydraulic circuit suggestion: HA version
Slide21Unit will be protected with an external power line switch IL, connected to power line by a cable (Line, Neutral earth) with section have to be appropriately calculated and fixed on IG unit main
switch
Voltage line tollerance+/-10
%
The use of IL with suitable cut off and differential protection is mandatory as the earth cable
ANK045HA°°°°5
ANK Electrical Features
Slide22ANK Electrical Features
Auxiliary Electrical Inputs:
Remote start/stop IA control
Remote cool/heat C/F control
Remote alarm AE indication
Remote DHW-TWS call control Remote force-off TRA control
Remote EH-Boiler RCR control
Aux. connection here
Terminal plugged here
Slide23ANK Wiring Diagram
Slide24ANK Wiring Diagram
Slide25ANK Wiring Diagram
Slide26ANK Wiring Diagram
Slide27PR3 Remote S
imple Panel
Max remote distance 150 mt
Cable 7 poles, min section per each wires 0.5 mm
2, 20 AWGConnection
on unit internal green terminal
Commands
Remote unit ON-OFF
Heating-cooling selection
Alarms reset by fast on-off button selection (3 x hour)
ANK Accessories
Slide28ANK Accessories
MODU-485A
: RS-485 interface card for supervisor system
MODBUS RTU protocol
8bits, parity none, 2 stop bits
To enable the communication go to INSTALLER menù psw 030 and to set:
Parameter J = supervisor address requested
Parameter L = baud rate (0=9600, 1=19200, 2=38400)
Parameter N = 1 to enable remote writings (setpoints, on-off, reset
alarms...)
Slide29VT
: antivibration kit fixed
under unit basement to stop vibration
transmission
ANK Accessories
Slide30ANK Accessories
AERWEB300
: To log and monitor unit datas
via Lan or GPRS connection
It is possible to control max 6 (aerweb300-6) or 18 (aerweb300-18)
Slide31ANK Accessories
Slide32ANK Accessories
MULTICONTROL
:
Can control up to 4 machines
equipped with moducontrol and RS485 cards installed in the same hydraulic system
Control
Chillers, according to the system capacity demand, can be driven by load, delta water temperature or in homogenous mode
Can control starting, stopping and separated operating setpoints (DHW and heating/cooling) for a maximum four units in autonomous mode or as slaves in a same system
Can be used also as remote control where the controls and units information are centralized
Slide33ANK Accessories
Electric heater
Electric heater and drip trail
KRB:
will be soonest available EH or EH plus drip trail to help the drainage
Slide34ANK MODUCONTROL Controller
Unit Terminal
Menus selector under
psw
Readings values
Start-stop selector
Press 3”
Parameter index
Alarms record selected
Alarms record
Settingsmenus call
Cooling led
Heating
dhw
led
Scrolling keys
Compressor call
Alarm led
Unit status led
Slide35ANK MODUCONTROL Controller
Unit Terminal Keys Meaning
Slide36ANK MODUCONTROL Controller
ANK dip setting:
1 - ON heat pump unit
2 – ON defrost by reversing cycle
3 – ON antifreeze set point unblocked4 – ON capacity control not activated
5 – ON safety steps not available6 – ON low water content not activated7 – OFF fan speed control not present
8 – OFF9 – OFF
10 – OFF11 – OFF12 – OFF
Trasducers configuration1 – OFF 2 - OFF
5 temperature sensors
2 trasducers
Outlet water regulation PISmart defrosting cyclesCompensation set pointDomestic hot water application with dedicated set point
Self adaptive working for plants with low water contentSmart managing of electric heaters
Slide37ANK Unit Commissioning
Checks Before to Start the Unit:
Unit placement: technical spaces respected
suitable support surface
Unit status: check unit status (no visible damages)
no visible oil leaks (regrigerant lost)Water circuit: check water connections respected
circuit water pressured all shut off valves opened
air evacuated water connections tightened (no leak)
Electrical : check section power cable earth cable connection IL power line switch selection
auxiliary inputs connected
all cables well tighneted
voltage line tollerance +/-10%
Unit has to be powered 24 hours before to warm compressor oil turning on main unit switch and checking that unit is switched off (no green led)
Slide38ANK Unit Commissioning Setting
Slide39ANK Unit Commissioning Settings
Resistance Management Menu psw 001
Slide40ANK Unit Commissioning Settings
Slide41ANK Unit Commissioning
Start Up
After
checks and settings go through READING menu
to verify accurate values read
ANK Unit Commissioning
Slide43ANK Unit Commissioning
Slide44ANK Refrigerant Circuit
Slide45ANK Refrigerant Circuit
Calibrated orifice
Liquid separator
Expansion vessel
Liquid accumulator
4 way valve
powered in cooling
Air exchanger distributor
Expansion valve
Dry filter
High pressure switch
609 PSI
Water filter
Transducers
Flow switch
Slide46ANK Control Details
Slide47ANK Control Details
Slide48ANK Control Details
Slide49ANK Control Details
When:
Decrease of suction pressure by more than 5.8 PSI
Outdoor temperature below 50˚F, coil temperature below 39˚F
Leaving water temperature is more than 86˚F (to reach confort quickly in cold starts)
Defrost end by suction pressure rise or maximum time
How:
Reverse cycle: under severe condition:
If the defrost is called in a shorter time for 3 times
If the suction pressure is less than 40.6 PSI
ANK Control Details - Defrost
Slide50ANK Control Details
Slide51ANK Control Details
Slide52ANK Control Details
Slide53ANK Control Details
Slide54ANK Control Details – Loads Defrost Management
Slide55ANK Control Details – Smart Starter Management
ANK machines are smart starter standard equipped
Can limit inrush currents to 40AACrms upon applying the control signal
Spoft starting is achieved within a 600ms interval
Managed by
Slide56ANK Control Details –
Fan Speed Controller
Slide57ANK Control Details –
Fan Speed Controller
Set HP
261PSI
Set HP + differential
Cooling Mode
Slide58ANK Control Details –
Fan Speed Controller
Heating Mode
Slide59ANK Control Details –
Screensavers
A screen saver can be inserted by index INSTALLER menu psw 030
Selection 1 Selection 2
Slide60ANK Troubleshooting
FACTORY psw 125
Alarm Summary Table
Slide61ANK Troubleshooting
Slide62ANK Troubleshooting
Slide63ANK Troubleshooting
AL001: CIRCUIT BREAKER
MTCCP contact opened or switched off
AL003: HIGH PRESSURE by HP SWITCH
AL012 : HIGH PRESSURE by HP TRASDUCERS
IN COOLING: fans off, air exchanger dirty, devices out of order, installation
IN HEATING: out of working limit, no enough water flow,gas charge, exp valve devices
AL004 : FLOW SWITCH
Water filter, air in the system, pump out, flowswitch out, shutt off valves closed, high pressure drops
AL008 : ANTIFREEZE
Water filter, low water set point, wrong antifreeze set point, low water volume
AL010 : HIGH DISCHARGE TEMPERATURE
Working limit, refrigerant charge, expansion valve, compressor
AL015 : LOW PRESSURE by TRASDUCERS
Working limit, refrigerant charge, fans out, air exchanger dirty, installation, device
Slide64ANK Maintenance
Periodical maintenance for correct functioning and long term duration to prevent failures
Hydraulic
Circuit:
Water
circuit filling, clean water filter, bleed air, pipes insulation, glycol check, water flow control
Electrical Circuit:
Safeties
efficiency test, voltage power supply control, loads absorption, connections tightness, cables quality, oil compressor and antifreeze heaters
Refrigerant Circuit:
Working parameters control HP, BP, Sh, Sc, safeties efficiency test, refrigerant pipes installation
Mechanical
Checks:
Screws tightning,
state of structure
Slide65Thank You For Your Time