Download The PPT/PDF document "NA CONSOLIDATION & SAFETY SYSTEMS" is the property of its rightful owner. Permission is granted to download and print the materials on this web site for personal, non-commercial use only, and to display it on your personal computer provided you do not modify the materials and that you retain all copyright notices contained in the materials. By downloading content from our website, you accept the terms of this agreement.
Slide1
Slide2NA CONSOLIDATION & SAFETY SYSTEMS
Y. Kadi, F.
Gautheron
, E.
Solodko
, M
.
Wilhelmsson
85
th
EA Technical Meeting, 4 July 2017
Slide3NA-CONS Study: Mandate
Deliver
a comprehensive proposal
for the North Experimental Area consolidation, including:All Beam related itemsInfrastructure & General ServicesCivil EngineeringThe Study shall propose implementation scenarios with all possible staging options, considering separately the periods:prior and during LS2 (highlighting urgent actions)between LS2 and LS3as well as during LS3
Y. Kadi, 04-07-2017
North Area Consolidation & Safety Systems
3
Slide4NA-CONS Study: Proposed Roadmap
Y. Kadi, 04-07-2017
North Area Consolidation & Safety Systems
4Identify most urgent items 2017/2018 and secure budgetDefine WBS/PBS and prepare related project documents
Discuss with concerned groups & participate to the
safety diagnostic (carried out by EN-DSO)
Identify
Consolidation/Upgrade activities together with resources and budget
needs
Slide5Flammable Gas Detection - SAFETY
BE-ICS
in NA-CONS
Safety = priority 1 (hopefully)Several meetings with EN-DSO, HSE, EPNew distribution of flammable gas detectors in EHN1 (D. Jaillet 83
rd EATM)Still 2 gas barracks (907, 909) but with less detectors (more inert gases)
2 mixing zones on Jura side + 2 mixing zones on Salève side
All PPE zones reviewed along H2, H4, H6 & H8 beam lines.
PPE zones of Jura side already treated, commissioned & validated (HSE)
Finalizing requirements for the
Salève
side. Hope for commissioning during next
YETS
EHN2, ECN3: no particular requirement. Usual
maintenanceECN3: hydrogen detection in the cavern (mixing area) and barrack (bldg. 918)
Y. Kadi, 04-07-2017
North Area Consolidation & Safety Systems
5
Slide6Gas Distribution - SAFETY
Y. Kadi, 04-07-2017
North Area Consolidation & Safety Systems
6EN-EA in NA-CONSLes solutions suivantes vont être mise en œuvre (planifiées, budgétisées) :
Doubler les soupapes sur les réseaux de gaz.Mise en conformité ATEX des baraques.
Les solutions suivantes sont proposées : Mise en conformité ATEX des points de distributions dans les halls.
Monitoring sur les consommations (débitmètre entrée – sortie).
Slide7Oxygen Deficiency Hazard (ODH) & CO2 -
SAFETY
BE-ICS in
NA-CONSODH risk in underground galleries - EHN1Gas network for nitrogen, argon, CO2, heliumNo air circulation in the galleriesCalculations for massive leaks: O2 from 21% to 18% in 72 sec.Time to escape, no needs for safety mask, but requires:Access control (already implemented) + ODH portable + CO2 detectionNeeds for ventilation. To be discussed with EN-CVODH risk in EHN2 galleries
Obsolete system but no plan for renovation before 2020 (LS2)ODH risk in ECN3 experimental cavern
Fully renovated in 2015. Detection in the krypton area. Possible upgrade (LS2)
Y. Kadi, 04-07-2017
North Area Consolidation & Safety Systems
7
Slide8Fire Detection - SAFETY
BE-ICS in
NA-CONS
Already in the framework of the SPS fire safety projectRisk to be assessed by HSE, status report requiredDetection technology to be deployedFire doors? Segmentation along beam lines? ….not necessary same needs than SPSIssues already known:Absence of smoke evacuation in the NA beam tunnelsObsolete sprinklersSurface buildings: Evacuation alarm to be renovated
30 km of PVC pipe (air sampling network) must be removed
When? Post LS2. LS2 already heavily loaded
Y. Kadi, 04-07-2017
North Area Consolidation & Safety Systems
8
Slide9Cryogenics Installations -
TE-CRG
Meeting may 25
th with D. Delikalis & M. Capeans (TE-PPR)Items already treated (maintenance or consolidation):All compressors and cold boxes are OKUNICOS migration already performed for all the cryo controlsNA62 consolidation (LN2 transfer line for liquid krypton, valves) doneTo be consolidated or wishes to be:6 centrifugal pumps for experimental SC magnets (6x150 kCHF)
Urgent: 3.3kV cells for control and compressors (bldg. 895) -> EN-ELStop renting and purchase large LN2 storages
(2x20000 l + 1x50000 l)-> 440 kCHF (from a 2014 cost estimate): long term savings…
TE-CRG will prepare work units description by mid-July
Y. Kadi, 04-07-2017
North Area Consolidation & Safety Systems
9
Slide10Magnets -
TE-MSC
Current situation:
426 beam line magnets in totalSpares magnets are available for almost all the familiesActivities to be done for 2017: zero-field probe replacement, exchange of manifolds, ELETTA refurbishing, renovation of electrical interconnectionsPossible safety audit:Inspection not needed: TE-MSC aware of all the issues related to safety and reliabilityKnown issues: electrical safety conformity, water leaks, shimming of the coils, replacement of polyurethane pads for the magnets
supports
Energy Balance program upgrade:The program should be validated
by
physicists
Only ~116 solid yoke magnets can be replaced by laminated
ones
Some of these magnets are of the same families as for
the
EA
Future actions:
TE-MSC to provide to EN-DSO past history of leaks/incidents
TE-MSC to prepare work unit description
EN-DSO to update risk assessment and issue
recommendations
Y. Kadi, 04-07-2017
North Area Consolidation & Safety Systems
10
Slide11Civil Engineering -
SMB-SE
Issues which can potentially be included in the consolidation program
:Infiltration of ground water in the tunnelsMotorized doors renovationFalse floorsDrainage networksRoofsIn case of upgrade, all the works will be contemplated in the context of the equipment groups/users future requirements;
Items that should be included in possible safety diagnostic:
Systems for smoke evacuation (sky domes more appropriate than extraction)
Presence of asbestos
Future actions:
EN-EA to contact TSOs and users of all NA buildings
SMB-SE to fill in the work unit description
documents
Y. Kadi, 04-07-2017
North Area Consolidation & Safety Systems
11
Slide12Cooling & Ventilation -
EN-CV
EN-CV group is well advanced in terms of identification of consolidation activities. Three work unit description documents were received a month ago.
The activities for 2017/2018:TDC2/TCC2 ventilation: 5/8 power cubicles already done. Renew remaining 3 power cubicles during YETS 2017/2018Chilled water renovation all along the years except during LS2BA80 and BA82: soft start of the pumpsActivities planned for LS2:
Chilled water pipe renovation
Renovation of the cooling towers power control system (building 893)
Replace backing of the cooling towers
Activities post-LS2:
Renovation of the ventilation system of all surface buildings (BAs)
Work on the compressed air system during the YETS and EYETS
Renovation of the Ventilation system of the gas building
Continue the soft start of the pumps
Future actions:
EN-CV to provide remaining work unit description
documents
Y. Kadi, 04-07-2017
North Area Consolidation & Safety Systems
12
Slide13Handling & Transport -
EN-HE
The activities for 2017/2018:
Currently no activities are to be done for this yearReplacement of lifts alarm (not with NA-CONS budget)Activities to be done during LS2:B. 889 (BA 80) crane revamping + remote operationsB. 888 (EHN2) cranes PR-0539 & PR-0545 revamping or electrical
renovationB. 886 (TCC2) cranes PR-0537 & PR-0544
revamping or replacement
Activities
post-LS2:
B. 889 (BA 80)
lift
B. 912 (PP851)
lift
BAA85
liftFuture actions:EN-HE to provide work unit description
documents
Y. Kadi, 04-07-2017North Area Consolidation & Safety Systems
13
Slide14Secondary
Beam
Lines -
EN-EAUrgent Safety requirementsBuffer zone and RP monitor in BA80SUSI for EHN2Closing of galleries in EHN1 and ODHKey cabinet in EHN1
Dry vacuum pumps for TCC2Gas
safety (safety valves, check valves,
purging
systems
)
Collimator
renovation
9 collimators in total this year (program will
continue)Beam
line items renovations
Fellows
and TTE for NA-CONS
Study
PJAS
for
Cesar
Bend
7
Gas
rack for XCET
Note
that
gas
renovation
measures
are
reported
separately
Y. Kadi, 04-07-2017
North Area Consolidation & Safety Systems
14
Slide15Summary
Y. Kadi, 04-07-2017
North Area Consolidation & Safety Systems
15Discussion with concerned groups still ongoing: HSE-RP, EN-STI, EN-EL, TE-EPC, TE-MPE, TE-VSC, BE-BI, BE-CO, IT-CSBudget 2017 under control: 82% committed
Target for 2017 to 2027:
Identify
Consolidation/Upgrade activities together with resources and budget
needs